WARNING

For your protection please read the following:

Water and moisture:

Electrical devices should not be used near water ( as per example,

near a bathtub, washbasin, kitchen sink, laundry tub, wet basement or swimming pool ).
Care should be taken such that objects do not have the opportunity to fall, and that liquid
is never spilled onto or into the device enclosure through openings.

Power Sources:

An electrical device must  be connected to a mains power source in strict

accordance with the supplied  product owners manual.  Please verify that the

mains

AC

voltage speci

fi

ed in the product manual matches those requirements indicated on the unit

and the

voltage provided to your location by the power company.

AC

Grounding:

Adequate precautions should be taken so that the grounding provisions built

into an electrical product are never defeated.

Power Cords:

Pass Labs provides a power supply cord that meets all legislated

requirements for the market in which the product was originally sold.  If you choose to
substitute an after-market product we urge you to choose one that is fully safety rated by
the necessary local authority.

Power Cord Protection:

Power supply cords should be routed so that they are not likely

to be walked on, abraded, or pinched by items placed on or against them, paying particular
attention to cords where they enter plugs or exit from a device. Never under any
circumstance insert a cut or damaged power cord into a mains power socket.

Power and Signal:

Cables should never be connected / disconnected with equipment

powered up.  Failure to heed this warning may damage or destroy equipment.

Ventilation:

Power-ampli

fi

ers run hot, but you should be able to place your hands on

them without discomfort.  You must allow for this heat in installation, by providing for
free air circulation around the product.  Electronics should not be subjected to sources of
excessive radiant heat. Excessive heat can shorten the life of the product and may cause
the electronics to self protect and shut down.

Servicing:

To reduce the risk of

fi

re, electrical shock or other injuries, the user should not

attempt to service the device beyond that which is described in the operating instructions.
All other servicing must be referred to quali

fi

ed service personnel.

For Units With Externally Accessible Fuse Receptacle:

Unplug the device from all

sources of power before changing  or inspecting any fuse.  Replace fuse with one of same
physical size, type and rating as that speci

fi

ed by the manufacturer for that product.

Quick Setup:

Unpacking your

-250

INT

The

-250 is heavy - please make sure you have help to remove the

-250 from the

INT

INT

packing and to place the amp where you want it.

Included in the box are a remote control and a power cord. You will need these so don

t throw

them away with the empty box. In fact you should keep the empty box as well.

Place the ampli

fi

er close to where you intend to use it. Just leave enough access so you can

connect the inputs and speaker cables.

Plug in the amp into the

. Turn on the

power switch. At this point you should have the

AC

AC

blue

in the center of the meter on. Push the

power

button on the faceplate a few times.

LED

The amp should cycle on and off (display and meter lights will come on and go off).

Turn the amp

off

from the faceplate. Now you should be ready to connect your sources and

speakers.

Quick Connections:

Connect your sources to the inputs. There are four inputs, two with

and

and two

XLR

RCA

with

only. The

and

inputs on

1 (and

2) are connected so use

RCA

XLR

RCA

INPUT

INPUT

XLR

RCA

INPUT

RCA

XLR

or

but not both. When using

1 & 2 with

s you should have the

shorting jumpers in place.

The Preamp Outputs can be used to drive a second system, a subwoofer or other ampli

fi

ers

for bi-amping. These output are live when the amp is live and

when the amp is

MUTED

MUTED.

The speaker binding posts can accept spades, banana plugs or bare wire. They also have a built
in torque limiting ratchet system to prevent over tightening and damage to the binding posts.

Содержание INT-250

Страница 1: ...PASS INT 250 250W Integrated Amp AB ...

Страница 2: ...r supply cords should be routed so that they are not likely to be walked on abraded or pinched by items placed on or against them paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance insert a cut or damaged power cord into a mains power socket Power and Signal Cables should never be connected disconnected with equipment powered up Failure t...

Страница 3: ...mes LED Theamp shouldcycleon and off displayand meterlightswillcomeon and go off Turn the amp off from the faceplate Now you should be ready to connect your sources and speakers QuickConnections Connect your sources to the inputs There are four inputs two with and and two XLR RCA with only The and inputs on 1 and 2 are connected so use RCA XLR RCA INPUT INPUT XLR RCA INPUT RCA XLR or but not both ...

Страница 4: ...or 9 Mute button LED 1 Right Speaker Connection 2 Preamp outputs 3 Power Switch RCA XLR AC 4 Mains Inlet 6 Preamp inputs AC RCA XLR 7 Signal Ground 8 Left Speaker Connection Preamp Output L R R L Preamp Inputs 1 2 3 4 Right Right Left Left Left Right Left Right Jumper must be used with single ended input No user serviceable parts inside 3 1 2 Signal Gnd Pass Laboratories Auburn CA 95602 AC Mains 2...

Страница 5: ...250 draws less than 0 5 watts Front Display Meter The display show volume level in one dB steps from 0 to 63 The meter operates LED slightly different from our amplifiers in that this meter doesn t show bias but output voltage Input selection The inputs can be selected by the four buttons on the face plate or the input buttons 1 4 on the remote Volume control The volume level can be set by using t...

Страница 6: ...ican product must be returned to the country of origin for warranty service Foreign distributors are only required to offer warranty service on Pass Laboratories product thattheyhaveimported verifiable byserialnumber Please note Conditions of warranty service and customer rights for product purchased outsidetheUnitedStatesmayvarydepending upon thedistributorand local laws Pleasecheck withyourlocal...

Страница 7: ...Outputs 2 Power Output ch 8 ohm 250 Watts Power Output ch 4 ohm 500 Watts Type Class AB Frequency Response 6dB 80 z KH Input Impedance Kohms 45 Distortion 1 z full power 1 KH Damping Factor 150 Slew Rate V uS 50 Output Noise uV 250 Input dB 60 CMRR DC Offset V 0 05 Leaves Class A at pk Watts 15 Power Consumption W 375 Temperature deg C 53 Dimensions W x D x H 19 x 21 25 x 9 06 Weight 105 LBS Ship ...