The XP-30 is a modular preamplifier consisting of one control / power supply chassis 
and additional gain chassis, each containing the analog circuits of a single channel.  
The XP-30 is meant to typically be used as a two-channel product, but you can use 
the control chassis to serve up to six channels. 
 
Each channel individually provides master and slave outputs.  The relative level 
between the master and slave outputs of each channel is adjustable by a knob on 
the front panel of each individual gain chassis.  If you have ever wanted to bi-amp 
your loudspeakers, you might appreciate that this feature allows easy use of 
different types of amplifiers for the low vs the high frequencies, adjusting the relative 
levels as needed.  If you need big power and control on the bottom but want the 
sweet character of tubes on the top, you may wonder how you ever got along 
without this.  Or why other companies don't offer it. 
 
It is even useful when the same types of amplifiers are used – typically without the 
full load on each amplifier the subjective balance still needs minor tweaking. 
 
All connected gain chassis respond to the master level adjustment on the main 
control chassis through a completely new volume control covering a range of 100 dB 
in precise 1 dB steps.   
 
Both outputs of each channel are offered as single-ended and balanced outputs 
having the same gain and impedance and both may be used simultaneously with no 
degradation.   
 
There are five (5) regular inputs, a special home theater bypass input and tape input 
for those needing any side loops for recording or signal processing.   
 
The control chassis also supports a mono function between the separate different 
analog stage chassis. 
 
The power supply in the control chassis is large enough for somebody else's power 
amplifier.  It contains a pair of highly efficient, low-noise Plitron transformers in dual 
mono topologies, emi filtering, large capacitance reservoirs, and of course the 
isolation that comes with being in a different chassis from the analog gain stages. 
 
Something else that was on Nelson's wish list – the ability to drive an amplifier 
output stage by itself:  Do you require a preamplifier deliver a fraction of a volt to the 
power amplifier or peaks in excess of 50 volts to a balanced no-feedback follower 
output stage? 
 
The XP-30 is fully capable of both tasks at once.  The internal gain of each stage 
can be boosted another 16 dB via an internal jumper and the preamp can serve as 
the low source impedance front end to the new generation of Class A power 
followers.  Don't laugh – they already are for sale, and there are more coming your 
way.  If you have an XP-30 you won't have to buy a new preamp... 

Содержание XP-30

Страница 1: ...XP 30 Owner s Manual Rev 0 Oct 3 2011 ...

Страница 2: ...We want you to anticipate listening to your entire record collection again and again As part of the process in developing the XP 30 we began by uniformly upgrading the playback systems of our listening group We do not do AB or ABX testing our people live with prototypes as long as they like in their own system and only one component gets changed at a time This allows a close duplication of our cus...

Страница 3: ...ange of 100 dB in precise 1 dB steps Both outputs of each channel are offered as single ended and balanced outputs having the same gain and impedance and both may be used simultaneously with no degradation There are five 5 regular inputs a special home theater bypass input and tape input for those needing any side loops for recording or signal processing The control chassis also supports a mono fu...

Страница 4: ...wider bandwidth than its predecessor and also features a dramatically higher input impedance This improved version of our symmetric topology sounds so exquisite that that it has also been adopted in the new Dual Chassis Amplifier prototypes Pass Labs has made large purchases of discontinued Toshiba Jfets and Mosfets to support production of this new gain stage for the next ten years Each of these ...

Страница 5: ...ber that we track all hardware and software details and history of an individual product unit Power Connection As with all audio electronics the power cable should be the last thing attached and the first one removed any time you hook up or remove equipment from the signal chain First The preamplifier s voltage and current ratings are indicated by affixed tag on the rear of the preamplifier s powe...

Страница 6: ...ut a little is helpful On the rear of each control chassis are two identical DIN 25 sockets in parallel with one another You may connect either socket to the control chassis as previously indicated they are identical The second socket provides daisy chain capability for additional gain channels The DIN 25 connecting cables only communicate power and control commands to the gain stages At no time d...

Страница 7: ... home theater Pass thru command is simply a software setting that selects input 6 and sets the gain to 0 dB with a minimum of keystrokes The keystroke shortcut selects input 6 and slowly advances the volume control to step 89 starting from 0 The slow advance of level is intentional 0dB step 89 is appropriate for a home theater processor it is however dangerously high for most source components As ...

Страница 8: ...tion is selected only from the front panel it is not available from the hand remote When mono is selected rather than creating a true mono signal it creates a frequency dependent blend of signal from two chassis The blend has been chosen such that it minimizes noise while maximizing information transfer The two blended gain chassis are joined to one another by a special XLR cable The blend functio...

Страница 9: ...y safety rated by the necessary local authority Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on abraded or pinched by items placed on or against them paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance insert a cut or damaged power cord into a mains power socket Power and Signal Cables ...

Страница 10: ... total 60 ohm per phase Slave balanced 200 ohms total 100 ohm per phase Main RCA 120 ohm Slave RCA 120 ohm Input impedance 42 k Ohm CMRR typical 65 dB 1KHz Crosstalk broadband typical 100 dB 1KHz Signal to Noise Ratio 110 dB Ref 5V Residual Noise 20 Hz 20 kHz 20 uV un weighted max Power Consumption 45 watts as two channel 15 watts additional per additional channel Dimensions chassis 17 W x 12 D x ...

Страница 11: ...nty on factory repair is 60 days and covers only the scope of the original repair Non North America customers should consult with their original Pass Labs dealer or distributor for warranty repair instruction prior to contacting the factory or shipping product to the factory for repair Non North American product must be returned to the country of origin for warrantee service Foreign distributors a...

Страница 12: ...cloned product Pass Laboratories does not offer products in voltages intended for international markets either to authorized Pass Labs dealers or to third parties located in the United States or Canada For more information please contact Pass Laboratories Inc 2011 Pass Laboratories Inc Pass PASS Pass Labs Pass Laboratories Supersymmetery Aleph and Zen are all registered trademarks of Pass Laborato...