background image

7

XP-12_om_10.17

BALANCE: Pressing balance left (<) or balance right (>) will increase 

the level in the left or right speaker, depending upon which button 

is pushed.

VOLUME:  Pressing the increase (^) button or the decrease (v) 

button will shift the volume setting 1dB, holding a button down will 

increase or decrease the level until such time as you either release 

pressure on the button or reach the limits of the volume control.

PASS THRU:  Pushing this button twice, sets the pre-amplifier to 

volume step 89 (0 dB) and input 5.   As an added precaution when 

“pass through” is selected the volume ramps upto 89. 

 

This is to prevent nasty surprises when “pass thru” is selected 

accidentally. The ramp up sequence can be stopped at any time 

by hitting any button on the remote.

The button must be pressed again to exit “Pass Thru” and unlock 

the other command selections.

DISPLAY:  The default setting for the display is “bright”, pressing 

the display button once changes the display to its “dim” or “low 

intensity” setting, pressing the button a second time selects “off” 

for the display.  When “off” is selected any other control function 

will cause the display to indicate product operational status for 

approximately 7 seconds and then the display will once again 

blank.  Pressing the display button a third time cycles back to a 

“bright display”

We recommend the use of the balanced output mode where 

possible.  Balanced input to power-amplifiers will typically retain the 

character of the input mode, but offers less distortion, less noise, 

more gain, and more voltage swing, without compromising the 

sound.

With balanced operation, the common mode rejection of the 

preamp reflects the intrinsic common mode rejection of the 

topology, the matching of the gain devices, and the matching of 

the attenuator channels.  In this case we have been able to keep 

the total mismatch to about .1%, for a common mode rejection of 

approximately  -60 dB.

The input system of the preamplifier will exhibit full common 

mode noise rejection with passive balanced sources, where the 

negative input is connected to ground at the source through 

the appropriate source impedance.  This allows adaptation of 

unbalanced sources to balanced operation with passive cable 

connections in a manner that achieves the noise rejection of active 

balanced sources.

Содержание XP-12

Страница 1: ...1 XP 12_om_10 17 PASS TM XP 12 Owner s Manual ...

Страница 2: ... after market product we urge you to choose one that is fully safety rated by the necessary local authority Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on abraded or pinched by items placed on or against them paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance insert a cut or damaged p...

Страница 3: ...th vacuum impregnating and epoxy fill This gives us a very quiet transformer both electrically and mechanically The power supply circuitry itself is also lower noise and has additional filtering a little more complicated but worth it The XP 12 uses the single stage volume control borrowed from the XS line preamp This gives us one hundred 1 dB steps with lower noise and distortion while removing so...

Страница 4: ...ation with an earth ground provided by the users AC outlet Do not defeat this ground There are a total of five inputs Two of the five inputs are balanced XLR only The other three inputs are single ended only There are two pairs of outputs available with identical gain structure One pair Balanced one pair single ended Balanced inputs and outputs are via XLR connectors Single ended inputs and output...

Страница 5: ... discussed at length later in this manual The two select arrows logically control selections of the various inputs to the preamplifier Before selecting the theatre pass through pass thru option it is imperative that the input device on input number 5 has its gain set to minimum Failure to follow this precaution could result in a volume level intolerable to both ears and speakers The standard 2 vol...

Страница 6: ...cking of the volume of the two balanced channels is possible with accuracy unavailable on any ordinary volume control assuring precise level steps and high common mode rejection in balanced circuits Wayne Colburn s exceptional volume control in conjunction with the fluorescent display gives the user ability to replicate volume levels with absolute accuracy in steps of roughly 1 dB The remote contr...

Страница 7: ...he display When off is selected any other control function will cause the display to indicate product operational status for approximately 7 seconds and then the display will once again blank Pressing the display button a third time cycles back to a bright display We recommend the use of the balanced output mode where possible Balanced input to power amplifiers will typically retain the character ...

Страница 8: ...d it ever be necessary to update the software that controls the functioning of the preamp only the socketed micro processor need be changed Muting relays which delay connection during turn on and shut off the output when insufficient power supply is available to maintain regulation guard the output of the preamplifier and offer protection to the power amplifier and loudspeakers XP 12 Specs Power c...

Страница 9: ...North America customers should consult with their original Pass Labs dealer or distributor for warranty repair instruction prior to contacting the factory or shipping product to the factory for repair Non North American product must be returned to the country of origin for warranty service Foreign distributors are only required to offer warranty service on Pass Laboratories product that they have ...

Страница 10: ... Labs dealers or to third parties located in the United States or Canada For more information please contact Pass Laboratories Inc Pass PASS Pass Labs Pass Laboratories Supersymmetery Aleph and Zen and are all registered trademarks of Pass Laboratories Inc and all rights thereto are protected by law PASS Pass Laboratories Inc 13395 New Airport Rd Suite G Auburn CA 95602 voice 530 878 5350 fax 530 ...

Отзывы: