background image

6

XA60.5 Owner’s Manual

 The amplifier’s voltage and current rating are indicated on the 
rear panel.  It will be either 230 volts, 115 volts or 100 volts.  The 
larger amplifiers have a circuit breaker of  the appropriate capacity. 
The smaller power amplifiers use a slow-blow 3AG type fuse.  The 
frequency rating of  the AC line source is 50 to 60 Hz.  Please verify 
that the amplifiers indicated voltage requirements are consistent with 
the supplied voltage and current at your location.

On the rear panel you will find both RCA and XLR type input 
connections for single-ended or balanced inputs.  If  you use the RCA 
input, be certain that the XLR connector has a gold shorting plug 
between pins 1 and 3, which connects the “minus” input to ground, 
otherwise the amplifier will not operate properly.  If  you lose this 
plug, just contact the factory – we give them away all the time.

The question comes up all the time – are balanced inputs (XLR) 
better than single-ended (RCA)?  The answer is that balanced lines 
generally give lower noise and slightly less distortion.  They are 
recommended unless your favorite source component has only RCA 
outputs.

Also on the rear panel are the output connections for the 
loudspeakers.  On stereo amplifiers there is one pair per channel, and 
on mono amplifiers we provide two pairs wired in parallel to facilitate 
“bi-wiring” a loudspeaker.  As you are probably familiar, the red one 
is positive polarity, and the black one is negative.

Please note that, being a balanced output, both of  these terminals 
are electrically live – neither is grounded and should not be treated 
as ground.  This is particularly important if  you are using the 
output of  the amp to also drive a subwoofer amplifier or other 
active component.  If  there is any question, please contact the 
manufacturers of  the products involved – both they and we will be 
happy to advise you.

If  you happen to need a clean signal ground connection for any 
reason, we provide a dedicated 5 way binding post just for that on 
the rear of  the amplifier.

On the rear panel you will also find a pair of  5 way binding posts 
for external turn-on control.  Applying 5 to 12 volts DC at this 
connection will override the front panel stand-by switch and turn the 
amplifier on.

Содержание XA60.5

Страница 1: ...1 pass XA60 5 Owner s Manual May 17 2007 ...

Страница 2: ...power amplifiers based on the SuperSymmetric topology U S Patent 5 376 899 which elicits high power and performance from simple circuits with minimal feedback The first X amplifier the X1000 was intended as the premier example of the power of this principle delivering 1000 watts rms into 8 ohms at low distortion By itself of course this is no miracle but you have to consider that products with com...

Страница 3: ...ts are the result of trial and error and extensive listening Measurement of performance is important to us and we feel that well designed product sounds good and measures good Apparently it is possible to make an amplifier which measures well but which does not please the ears and so we let our ears be the final judge X 5 and XA 5 amplifiers utilize the same basic circuit topology and gain devices...

Страница 4: ...carefully and critically to our amplifiers with a wide variety of associated equipment and we take our time with it Musical performance is most important and is the basis of our success over the years It s true that we also value the other things The design and manufacturing decisions have to balance subjective performance against reliability cost specs and ego in approximately that order That is ...

Страница 5: ... minimum noise this switch should be toggled in stand by mode We have provided a standard IEC power cord that fits into the standard 15 amp IEC receptacle at the rear of the amplifier chassis With the exception of the largest of the X and XA series there is no difficulty running two amplifiers on a single 15 amp circuit Given the high current draw we generally do not recommend active line conditio...

Страница 6: ... noise and slightly less distortion They are recommended unless your favorite source component has only RCA outputs Also on the rear panel are the output connections for the loudspeakers On stereo amplifiers there is one pair per channel and on mono amplifiers we provide two pairs wired in parallel to facilitate bi wiring a loudspeaker As you are probably familiar the red one is positive polarity ...

Страница 7: ...power cord from the wall while you connect the speakers and inputs Check to make certain that the loudspeaker cables aren t shorted at the loudspeaker end connect speaker cables to the output binding posts on the amplifiers observing correct polarity The output binding posts will accept either bare wire or spades Regulatory agencies in many countries have banned binding posts that will accept a ba...

Страница 8: ...mall comfort to the few but take it easy and give us a call if you have problems People are interested in how long it takes for these amplifiers to break in Depending on the resolution of the rest of your audio chain you may or may not notice any break in of the amplifier beyond the first few hours of operation You will very likely notice the difference in sonic character between cold and normal o...

Страница 9: ...uple hundred feet Fortunately this amplifier is not sensitive to the capacitive inductive character of some of the specialty speaker cables so feel free to experiment We have found that about 90 per cent of bad sounding cables are really bad sounding connections and we recommend that attention be paid to cleanliness of electrical contact surfaces and proper connector fit Speaker cables should be f...

Страница 10: ...built industrial design not a frail tube circuit run on the brink of catastrophic failure If it breaks we will simply get it fixed so sleep well Pass Laboratories PO Box 219 24449 Foresthill Rd Foresthill CA 95631 USA www passlabs com sales passlabs com service passlabas com tel 530 367 3690 fax 530 367 2193 pass Pass Pass Labs Pass Laboratories Supersymmetery Aleph and Zen and are all registered ...

Страница 11: ... 1 60 W Maximum Output Voltage 35 volts Maximum Output Current 20 amps Input Impedance 30 kohm balanced 15 kohm unbalanced Damping factor 150 ref 8 ohms nominal Slew rate 50 V uS Output Noise 150 uV unweighted 20 20 kHz Random noise floor 1 uV Dynamic range 150 dB random noise floor to peak output Balanced CMRR Balanced CMRR Balanced CMRR 60 dB 1 KHz DC offset DC offset DC offset 50 mv Power Consu...

Страница 12: ...e and customer rights for product purchased outside the United States may vary depending upon the distributor and local laws Please check with your local distributor for specific information Any modifications to Pass Laboratories products that have not received written factory approval nullify all claims and void the warranty Should a modified product be returned to the factory for repair the owne...

Страница 13: ...wer Cord Protection Power supply cords should be routed so that they are not likely to be walked on abraded or pinched by items placed on or against them paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance Never under any circumstance insert a cut or damaged power cord into a mains power socket insert a cut or damaged power cord into a mai...

Отзывы: