ADVANCED OPERATION

Groups

You can use the Group feature to control multiple LightSense™ wireless fan

controls from one location. Binding the fan controls together in the same Group

enables them to work in exactly the same way, from any of the control

locations.
You can also Group one or more LightSense PSWCS Wireless Multilocation

Controllers with a single fan control to control one fan circuit from multiple

locations.
You can include other LightSense wireless devices in the Group. Just

remember that all devices in the Group operate when one member operates. If

you group a dimmer with a fan control, the fan speed will increase when you

increase the brightness from the dimmer. Conversely, if you press a button on

the fan control to reduce the fan speed, the lights will dim.
Set the House ID (see Set House ID) before setting up Groups.

1. Go to any device that you want to include in the Group. Press

. The

device LED flashes yellow. Devices not currently in the group flash green.

You now have 5 minutes to complete this process.

2. To include or exclude a device in the Group press

on the device until the

LED changes color.

Yellow

flashing LED = Included in the Group

Green

flashing LED = NOT included in the Group

If you get to a device and it is NOT flashing, see TROUBLESHOOTING.

3. Return to the device used in step 1 and press

to terminate Group

binding. All LEDs revert to solid green.

Scene Control

The LightSense Wireless Fan Control may be easily incorporated into room and

whole house preset scenes. After binding the fan control to the desired scene,

as described in the scene controller installation instructions (PSWCH, PSWCR,

PSWRH, or PSWRR) set the fan speed by pressing one of the speed buttons

or

or

.

Note that the PSWCR and PSWRR wireless room scene controllers’ default

operation for the E scene button and the

paddle does not turn off the

PSWCF fan control. You can manually add the fan so that it is included when

“all off” function is invoked at the room scene controller.

The

LightSense Installation Guide provides more information about configuring

scenes. Application support information and the

LightSense Installation Guide

are available at www.passandseymour.com.

Содержание legrand LightSense PSWCF

Страница 1: ...ns Voltage 120VAC 60Hz Operating Temperature 32 F to 104 F 0 C to 40 C Maximum Load Rating 1 5A Load Type Compatibility Up to two ceiling fan motors U S Patent 6 175 220 Other utility design and foreign patents pending Syracuse NY 13221 4822 800 223 4185 www passandseymour com ...

Страница 2: ...n selected areas They use the 900MHz band for high speed control communication Using the patented frequency agile Top Dog technology LightSense wireless devices avoid interference with other 900MHz devices such as cordless phones and baby monitors INSTALL IN COMPLIANCE WITH ALL APPLICABLE CODES STANDARDS Failure to follow these instructions may cause personal injury or equipment damage Call 800 22...

Страница 3: ...o the GND terminal on the back of the unit 5 Connect the white Neutral fan control wire to the white supply and white load wires using a wire nut 6 Connect the black fan control wire to the black supply Line using a wire nut 7 Connect the red fan control wire to the black load wire using a wire nut 8 Attach the wall plate 9 Switch the circuit breaker back ON LOAD LINE GND Supply Wires Load Wires N...

Страница 4: ...til the LED changes to solid green about 2 seconds All device LEDs in the house change to solid green indicating house binding is complete Adding a Device to an Existing Installation If you re adding or replacing a device in a LightSense wireless installation that is already operating the new device must acquire the same House ID as the other LightSense wireless devices in the house After the new ...

Страница 5: ... below When you see touch the top of the paddle as directed When you see touch the bottom of the paddle as directed The wireless fan control may feel warm to the touch during normal operation Fan Maintenance When fan maintenance is required use the Air Gap Isolation feature for safety To activate the feature Press FIRMLY so that the paddle clicks and latches in Make sure the status LED is extingui...

Страница 6: ...group flash green You now have 5 minutes to complete this process 2 To include or exclude a device in the Group press on the device until the LED changes color Yellow flashing LED Included in the Group Green flashing LED NOT included in the Group If you get to a device and it is NOT flashing see TROUBLESHOOTING 3 Return to the device used in step 1 and press to terminate Group binding All LEDs rev...

Страница 7: ... See the PSWCR or PSWRR wireless room scene controller instructions if one is present I made a configuration mistake I need to start over You can reset any LightSense wireless device to factory default settings by pressing and holding until the LED changes to solid yellow approximately 10 seconds During the process the LED flashes yellow and when complete it changes to solid yellow The device can ...

Страница 8: ...ount equal to consumer s purchase price Such remedy is IN LIEU OF ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Such remedy by Pass Seymour does not include or cover cost of labor for removal or reinstallation of the product ALL OTHER FURTHER ELEMENTS OF DAMAGE INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF ANY AND ALL EXPRESSED OR IMPLIED WA...

Отзывы: