![Pason WITS Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/pason/wits/wits_user-manual_761764036.webp)
Revised May 1, 2019
Revision 25 of DOCU225, © Copyright
Page 36 of 44
Name
WITS
Code
EDR can
Receive
EDR Sends in
Full WITS
Mode
EDR Sends in
Half WITS
Mode
Record 18: Drill Stem Testing
Available Transmission Types: Time Based, Depth Based, or Request-Response
Date
1805
Time
1806
Nitrogen Pressure In
1815
Y
Y
UBD Flow Pressure
1816
Y
UBD Flow Temperature
1817
Y
Downhole Pressure 1
1818
Y
Y
Downhole Temperature
1819
Y
Y
Condensate Out
1820
Y
Y
Hydrocarbon Flow
1821
Y
Y
H2S
1826
Y
Nitrogen Volume In
1827
Y
Y
Total Gas Return
1828
Y
Y
Nitrogen Volume Out
1829
Y
Y
Water Out
1830
Y
Y
Water Nozzle
1831
Y
Y
Record 63: Pason
Available Transmission Types: Time Based, Depth Based, or Request-Response
Date
6305
Time
6306
Magnetic Toolface
6310
Y
Y
Gravity Toolface
6311
Y
Y
Magnetic Toolface
6339
Y
Y
Gravity Toolface
6340
Y
Y
4.12 Typical WITS Packets sent to Pason
A typical packet from a total gas detection system includes the following lines:
&&
01691234.56
01705.43
!!
The first four digits in a packet make up the WITS code. The digits that follow the WITS
code represent the measured value being sent. The WITS specification also includes the
carriage return and line feed control characters, <cr><lf>, at the end of each line.