12
MAINTENANCE
Paslode
®
tools are built for ease of maintenance. A few
simple details will assure trouble-free operation and long
tool life. Anyone who uses or maintains the tool must read
the safety and maintenance instructions. Study the sche-
matic drawing before starting any repairs on the tool.
Air-operated tools must be inspected periodically, and worn
or broken parts must be replaced to keep the tool operating
safely and ef
fi
ciently. Also the items on the maintenance
chart must be checked often.
Cold Weather Care
When temperatures are below freezing, tools should be
kept warm by any convenient, safe method. If this is not
possible, the following procedure should be used to warm
up the tools.
❑
Reduce the regulated air pressure to 30 psi.
❑
Remove all fasteners from the tool.
❑
Collect an air line and blank
fi
re the tool. The reduced
air pressure will be enough to free-
fi
re the tool. Slow speed
operation tends to warm up the moving parts. Slowing up
the piston helps the bumper and the O-rings to become
springy.
❑
Once the tool is warmed up, readjust the regulator to the
proper working pressure and reload the tool.
❑
Tool operators working outdoors or in unheated areas in
extremely cold temperatures should also:
Use Paslode pneumatic oil with antifreeze in the
lubricator, Part No. 219090 (8oz.)
Once a week, depending on the amount of tool
use, take the tool apart and wash away any sludge
with tool cleaner (Paslode Part No. 219348)
to keep the tool operating ef
fi
ciently.
Cleaning the air-operated tools with solvents removes the
thin coating of grease applied to the cylinder wall and
O-rings at the factory. To replace this coating of grease,
use Chemplex grease (Paslode Part No. 403734).
❑
Open the drain on the air compressor tank to drain any
moisture at least daily in extremely cold or humid weather.
A few ounces of anti-freeze in the tank will keep the air
free of frost.
Testing the Tool After Servicing
After replacing any part or parts, it is important to check
the tool for proper operation. This ensures that the tool
was put together correctly, is safe to use, and will perform
the job properly.
❑
Ensure that all hardware is tight.
❑
Ensure that the work contacting element is installed
correctly in relation to the trigger, and that both parts move
freely.
❑
Ensure that the magazine is properly attached.
❑
Ensure that the required safety information on the tool
is legible.
❑
Use only Paslode approved fasteners in the tool, and
ensure that they are correct for the application.
❑
Ensure that a male air
fi
tting is securely connected to
the tool.
❑
Test the tool by driving fasteners into a workpiece iden-
tical to the tool's application.
❑
Check the tool for air leaks during testing and for the
proper sequence of operation.
❑
Ensure that all fasteners are driven to the same depth
and that the crown of the fastener is
fl
ush with the work-
piece.
Tool Lubrication
It is most important that the tool be properly lubricated by
keeping the air line lubricator
fi
lled and correctly adjusted.
Without proper lubrication the tool will not work properly
and parts will wear prematurely.
Use the proper lubricant in the air line lubricator. The
lubricator should be of low air
fl
ow or changing air
fl
ow
type, and should be kept
fi
lled to the correct level. Use
only Paslode recommended lubricants. Substitutes may
harm the rubber compounds in the tools O-rings and other
rubber parts. Paslode Part No. 403720 is a pneumatic
lubricating oil specially made for pneumatic applications.
If a
fi
lter/regulator/lubricator is not installed on the air sys-
tem, air operated tools should be lubricated at least once
a day with 6 to 20 drops of oil, depending on the work
environment, directly through the male
fi
tting in the tool
housing.
Most minor problems can be resolved quickly and eas-