IM50S COILMASTER MANUAL 8
CORRECT TOOL OPERATING PROCEDURES
= 200 nails
2.3 - 2.87mm
L 32mm to 50mm
Head type: Flat and Dome
Coating: Zinc plate, galv, stainless steel
CORRECT NAIL LOADING PROCEDURE
Open nose gate
1. Close magazine cover
first
2. Close nose gate and
latch
Open magazine cover
Place coil into magazine
Feed nails into nose
1
2
3
4
5
6
1
2
CORRECT REMOVAL OF EXCESS COLLATION TAPE
Fold tape at right angles
across front of tool nose.
Only then tear off collation.
Locking tab post support
collation
The tool has a locking tab which is designed to hold the
tape in place. Check locking tab is positioned correctly
in hole provided in collation tape. The correct use of
this locking tab ensures nails can not be dislodged from
collation strip during removal of excess tape.
WARNING:
Do not pull collation tape straight out of
nose. This incorrect action will dislodge nails already fed
into firing chamber and may cause nail to jam.
MAGAZINE NAIL LENGTH TRAY
Adjustable nail length tray for short nail support
Adjust nail length tray for long nail support