Instructional Manual and

Experiment Guide for the

PASCO scientific Model 

PK-9023

FIELD MAPPER

101

01 F

ooth

ills B

lvd. 

       

  •    

     P

. O. 

Box

 619

011 

      

     •

      

   Ro

sevi

lle, C

A   9

566

1-90

11  U

SA

Pho

ne (

916

) 786

-380

0    

   •  

       

FAX

 (91

6) 7

86-8

905

      

  •    

     T

WX 

910

-383

-204

0

scie

ntific

Instru

ctio

nal M

anu

al a

nd

Exp

erim

ent G

uide

 for th

e

PAS

CO

 scie

ntific

 Mo

del 

PK-

902

3

FIELD MAPPER

-

+

The PASCO scientific MODEL PK-9023 Field Mapper
consists of two basic elements.  The first is a carbon impreg-
nated paper in the resistance range of 5 K

 to 20 K

 per

square.  This paper forms the conducting medium or space
between the electrodes.  The second element is a conductive
ink dispensed from a pen.  The ink is produced from silver
particles in a suspension liquid.  As the ink dries, the silver
flakes settle on top of each other forming a conductive path,
(or  conductive ink electrodes).  The resistance of the ink is
between .03 and .05 

/cm for a 1 mm wide line.

Because the paper has a finite resistance, a current must flow
through it to produce a potential difference.  This current is
supplied by the conductive ink electrodes which causes a
potential drop to occur across the paths.  Because of the
large difference between the ink’s resistance and the
resistance of the paper, this potential drop is less than 1% of
that produced across the paper.  Therefore, for all practical
purposes the potential drop across the electrodes may be
considered negligible.

Equipment

Equipotential and Field Lines

It would be desirable that the potential measuring instrument
have an infinite impedance.  An electrometer such as the
PASCO Model ES-9054B would be optimal, however, a
standard electronic voltmeter such as PASCO's SE-9589
Handheld Digital Multimeter with a 10 M

 (or higher) input

impedance is sufficient.  Since this impedance is at least 100
times greater than that of the paper, the greatest distortion of
the field which can be produced by the voltmeter is approxi-
mately 1%.

The PK-9023 Field Mapper includes:

• 100 sheets of conductive paper with 23 x 30 cm grid
• a silver conductive ink pen for approximately 200 ft of

continuous line

• a corkboard working surface
• 10 push pins for attaching the paper to the board
• 3 wires for connecting the conductive paths
• a circle template for drawing the conductive paths.
• a large plastic tray for storing the paper and other

supplies

• Instruction manual and experiment guide.

The following supplies can be ordered separately
from PASCO scientific

Conductive ink pen

Model No. PK-9031B

100 sheets of 23 x 30 cm conductive paper with cm grid

Model No. PK-9025A

100 sheets of 30 x 46 cm conductive paper (without grid)

Model No. PK-9026A

Содержание PK-9023

Страница 1: ...800 FAX 916 786 8905 TWX 910 383 2040 scientific Instructional Manual and Experiment Guide for the PASCO scientific Model PK 9023 FIELD MAPPER 10101 Foothills Blvd P O Box 619011 Roseville CA 95661 90...

Страница 2: ......

Страница 3: ...Experiments Parallel Plate Capacitor 4 Point Source and Guard Ring 4 Dipoles of Opposite Charge 5 Dipoles of Like Charge 5 Floating Electrode 6 Floating Insulator 6 Line and Circular Source 7 Line an...

Страница 4: ...RETURN WITHOUT AN AUTHORIZATION When returning equipment for repair the units must be packed properly Carriers will not accept responsibility for damage caused by improper packing To be certain the u...

Страница 5: ...ecause of the large difference between the ink s resistance and the resistance of the paper this potential drop is less than 1 of that produced across the paper Therefore for all practical purposes th...

Страница 6: ...actually be conductive ink electrodes they will be referred to as electrodes 2 Draw the electrodes on the black paper see Figure 1 NOTE This is the most difficult and crucial part of the experiment Fo...

Страница 7: ...of separation one centimeter is a useful separation to use It is best to tape the two leads of the voltmeter together for this proce dure see Figure 7 The technique is to use the voltme ter leads to...

Страница 8: ...nt at which to place the voltmeter s ground lead Again probe with the other lead until the direction of highest potential difference is found Draw an arrow from the ground lead to the other lead and r...

Страница 9: ...whether equipotentials or field gradients are being mapped Parallel Plate Capacitor l d Electrodes DC Source Connecting wires Questions What is the field outside the capacitor plates How does the rat...

Страница 10: ...ite Charge What distortion of the field is produced by the large elec trode around the perimeter of the paper Dipoles of Opposite Charge Questions What is the relation between the direction of a maxim...

Страница 11: ...t is the potential of the circular electrode Of the area inside the electrode What effect would moving the circular electrode have Floating Insulator Rectangular cut out Before cutting the rectangular...

Страница 12: ...spacing of equipotentials affected by the increas ing diameter of the circular electrode Line and Sharp Point a a At first do not draw the two electrodes marked a Map the equipotentials Add the electr...

Страница 13: ...Turning to the Field Mapper we need to draw electrodes in the shape of the sources and sinks in the fluid flow to be examined Then the electric field lines which we plot coincide with the streamlines...

Страница 14: ...scientific 10 012 04346B Notes...

Страница 15: ...scientific 11 012 04346B Appendix...

Страница 16: ...scientific 12 012 04346B...

Страница 17: ...ting Technical Support Before you call the PASCO Technical Support staff it would be helpful to prepare the following infor mation If your problem is with the PASCO apparatus note Title and model numb...

Страница 18: ......

Отзывы: