Electrostatics Voltage Source
012-07038A
2
!
Address:
PASCO scientific
10101 Foothills Blvd.
P.O. Box 619011
Roseville, CA 95678-9011
Phone:
(916) 786-3800
FAX:
(916) 786-3292
Email:
Web:
www.pasco.com
Copyright Notice
The PASCO scientific 012-07038 instruction sheet is
copyrighted and all rights reserved. However,
permission is granted to non-profit educational
institutions for reproduction of any part of the
Electrostatics Voltage Source instruction sheet
providing the reproductions are used only for their
laboratories and are not sold for profit. Reproduction
under any other circumstances, without the written
consent of PASCO scientific, is prohibited.
Limited Warranty
PASCO scientific warrants the product to be free
from defects in materials and workmanship for a
period of one year from the date of shipment to the
customer. PASCO will repair or replace, at its option,
any part of the product which is deemed to be
defective in material or workmanship. The warranty
does not cover damage to the product caused by
abuse or improper use. Determination of whether a
product failure is the result of a manufacturing defect
or improper use by the customer shall be made solely
by PASCO scientific. Responsibility for the return of
equipment for warranty repair belongs to the
customer. Equipment must be properly packed to
prevent damage and shipped postage or freight
prepaid. (Damage caused by improper packing of the
equipment for return shipment will not be covered by
the warranty.) Shipping costs for returning the
equipment after repair will be paid by PASCO
scientific.
The high voltage outputs of the ES-9077 are designed
to charge objects in various electrostatics experiments.
These objects will typically present an essentially
infinite input resistance. Trying to drive other type of
loads may significantly load the high voltage outputs
and cause the output voltage to drop.
Repairs
There are no user serviceable parts inside the Voltage
Source.
If the ES-9077 Electrostatics Voltage Source requires
repair, it is strongly recommended that the unit be
returned to PASCO scientific. Because PASCO is
thoroughly familiar with the instrument and maintains a
complete stock of replacement parts, repairs can be
made quickly and at low cost.
Maintenance
There is no routine maintenance required for the
ES-9077. The outputs are factory adjusted to be
accurate within ±10%. The outputs cannot be checked
accurately using a standard multimeter or digital
multimeter because the input resistance of these
meters is low compared with that of the ES-9077 high-
voltage outputs. The outputs may be checked if a high
voltage probe (such as a Fluke 80K-40 HV Probe) is
available to connect to a digital multimeter; however
they will still measure slightly low. The actual voltage
may be calculated by knowing that the ES-9077 output
resistance is 120K ohms per volt (For example, the
1000 volt output has a series resistance of 120 Meg
ohms.) and the resistance of the high-voltage probe is
1000 Meg ohms.