MULTIZONE CONTROLLER INSTALLATION INSTRUCTIONS

7

IMPORTANT: 

The Multizone Controller should be situated in a well-ventilated location or position. Do not block the vents on the sides or top of the chassis. Proper 

ventilation is required for normal operation. Do not expose the unit to excessive dust and do not allow dust to build up on the unit and block the vent holes 

in the chassis. Do not place the Multizone Controller above or below heat-generating components such as another audio amplifier. Be sure to leave at 

least 2 inches of space to the sides of the chassis with open air flow above and below the unit. Before making any connections, ensure that all equipment 

is powered off and unplugged to prevent the possibility of personal injury or equipment damage due to electrical shock. 

INSTALLATION: 

1.  The Multizone Controller can be mounted in an equipment rack using the rack kit that is included with the Multizone Controller.

2.  Always disconnect the AC power cord before making any connections to the Multizone Controller.

3.  Use good quality 12-14 AWG 2 conductor stranded copper speaker wire for all speaker connections.

4.  Use good quality cat5e or cat6 cable and RJ45 connectors for all Multizone Controller-KP (keypads).

5.  The Multizone Controller includes a central keypad hub. All Multizone Controller-KP (keypads) will be home run back the hub. Keep the hub close the   

  Multizone Controller.

6.  Wire all cat5e/cat6 cables exactly the same using TIA/EIA 568A wiring. Do not use crossover cables.

IMPORTANT: All Multizone Controller-KP keypads must have their mode dip switches set properly before powering the system on. 

Set the three DIP switches on each Keypad Controller to one of the six identification patterns listed below. Each Keypad Controller connected to the same 

Master Controller/Amplifier must have a unique identification. Note that the identification is localized to each Master Controller/Amplifier device. If multiple 

Master Controllers are in use, each one will have its own set of keypads with the same identification numbers as keypads on another Master Controller. 

SETTING THE KEYPAD MODE DIP SWITCHES AND KEYPAD WIRING: 

Each Multizone Controller-KP shows a handy mode selection chart on the back of the keypad as follows: 

Switch in the up position is ON. Switch in the down position is OFF. 

IMPORTANT:

 Use a screwdriver to install the keypad. 

Using a power drill will damage the keypad. 

Содержание 309-585

Страница 1: ...6 SOURCE 6 ZONE DISTRIBUTED AUDIO SYSTEM UserManual...

Страница 2: ...2...

Страница 3: ...ations on your purchase of the 6 Source 6 Zone Distributed Audio System You have chosen a unit that provides the ultimate audio control in six stereo zones expandable to 18 stereo zones A true matrix...

Страница 4: ...ECTOR 115V 230V EXPANSION IN OUT Connect up to 3 systems MODE switch BRIDGE STEREO Four stereo RCA INPUTS 12Vdc PA trigger IN KEYPADS Input connects to keypad hub 12VDC TRIGGER OUTPUTS activate extern...

Страница 5: ...y The backlit LED display provides visual feedback of levels and source numbers The Multizone Controller keypad also provides an Infrared receiver which allows complete zone control via the included M...

Страница 6: ...ed on the keypad All keypad functions can be accessed using the remote control In addition to the keypad functions the remote control has a MUTE button to temporarily mute audio in the zone Once the M...

Страница 7: ...for all speaker connections 4 Use good quality cat5e or cat6 cable and RJ45 connectors for all Multizone Controller KP keypads 5 The Multizone Controller includes a central keypad hub All Multizone Co...

Страница 8: ...ltizone Controller KP keypads Use a good quality Cat5e 6 cable and crimp RJ45 jacks on each end of the cables The RJ45 jack plugs into the back panel of the keypads and the 6 x RJ45 jacks on the back...

Страница 9: ...ect more than one 8 ohm speaker to a single channel in bridge mode Never connect the Left Right channels of the amplifier together or combine the negative channels of the amplifier Improper speaker in...

Страница 10: ...ifier thus doubling the output power to 50 watts with a minimum speaker load of 8 ohms Remove approximately 5 inches from the cable jacket strip 1 4 of insulation from the speaker wire and twist the c...

Страница 11: ...onal amplifiers to expand the available power in a large zone or multiple zones The unit can be used as the master controller in large commercial audio systems with constant voltage 25 70V amplifiers...

Страница 12: ...not connect cables to both the Toslink and 3 5mm jack the same time Input 1 can be used as a paging or global all zones input When a source is connected to input 1 and 12Vdc is applied to the PA IN j...

Страница 13: ...is powered OFF 12Vdc is disconnected from the trigger output The triggers can be used to automatically switch peripheral equipment ON OFF The system also provides a master control 12Vdc trigger output...

Страница 14: ...of another Connect the included 18 pin ribbon cable to the EXPANSION OUTPUT terminal of the bottom unit and the other end of the ribbon cable to the EXPANSION INPUT terminal of the second and then th...

Страница 15: ...stems The DB 9 connector on the back of the unit supports bi directional RS 232 communication for third party automation systems An automation system can control all keypad and remote control function...

Страница 16: ...INSTALLATION RS 232 CONTROL RS 232 Serial Port Control continued Baud Rate 9600 8 N 1 DB9 Connector Pin out Tx Rx GND 16...

Страница 17: ...INSTALLATION RS 232 CONTROL RS 232 Serial Port Control continued Baud Rate 9600 8 N 1 DB9 Connector Pin out Tx Rx GND 17...

Страница 18: ...Input Sensitivity 250mv Amplifier Protection Overload Short Circuit Thermal Trigger Systems ON Voltage DC 12V Trigger External Mute Voltage DC 12V Infrared Frequency Band 38kHz Input Connectors 3 5mm...

Отзывы: