PARRY GBM2W Скачать руководство пользователя страница 3

 

 

 

INSTRUCTION REF: IN124           
ISSUE No.  1                                                   

 

DATE   23.02.06

 

Page 3 of 6

 

 
 

www.parry.co.uk 

 

WATER CHANGING ON MACHINES FITTED WITH A DRAIN 
 

ALWAYS SWITCH OFF THE MACHINE AND ISOLATE FROM THE MAINS SUPPLY 
BEFORE CHANGING THE WATER. 
 

1.

 

Unscrew the bung fitted to the drain tap and connect the drain  

      spout provided. 

 

2.

 

Place a suitable receptacle underneath the spout 

 

3.

 

Lift up the locking device and slide the drain tap across 

 

4.

 

After draining slide the tap back across and replace the bung 

 
 

ON MACHINES WITHOUT DRAINS FITTED 
 

1.

 

Turn off power supply 

2.

 

Tip machine upside down to empty 

 

Alternatively purchase a hand pump to empty out the tank 
 

Cleaning 

1.

 

Remove containers and clean in hot soapy water 

2.

 

With  the  containers  removed  wipe  down  the  machine  with  a  soft  cloth,  do  not  use 
abrasive materials. 

3.

 

Clean the tank on a regular basis to avoid scale build up, which could reduce the life 
of the element. 

4.

 

If  scale  has  built  up,  use  a  suitable  descaling  fluid  or  powder,  and  follow  product 
instructions. 

 

 
 
 
 
 
 
 
 
 
 

Отзывы: