INSTRUCTION REF: IN146-7 
DATE  - 25/02/16 
PAGE 9 of 14 
 

 

www.parry.co.uk 

TECHNICAL DETAILS 

MODEL: 7072 SALAMANDER GRILL         

Total Unit 

GAS 

OPERATING PRESSURE 

HEAT INPUT 

NATURAL   G20 

20mb/

8”      W.G. 

5.43  KW = 18527 Btu/h 

BUTANE     G30 

29mb/11.2” W.G. 

5.43  KW = 18527 Btu/h    

PROPANE  G31 

37mb/14.8” W.G. 

   5.43 KW =  18527 Btu/h 

G25 

25mb/10”    W.G. 

   5.6   KW =  19107 Btu/h       

             

   

            

GAS RATE 

 

 

NATURAL   G20 

0.5 M³/HR  

= 17.95 FT³/HR 

BUTANE     G30 

0.397 kg/HR 

= 0.875 Lb/HR 

PROPANE  G31 

0.391 kg/HR 

= 0.862 Lb/HR 

G25 @ 25mb 

0.62 M³/HR 

= 22.32 FT³/HR 

AIR FLOW RATE FOR COMBUSTION 20m³/HR 

= 5 M³/HR 

– 180 FT³/HR 

 
 

LOW RATE 

NATURAL   G20 

0.332 M³/HR 

BUTANE     G30 

0.480 Kg/HR 

PROPANE  G31 

0.480 Kg/HR 

G25 @ 25mb 

0.332 M³/HR 

 
INJECTORS 
Natural G20   = INJECT193 
Butane G30   = INJECT119 
Propane G31 = INJECT119 
G25 @ 25mb = INJECT193 
 
 

 

Содержание 7072

Страница 1: ...E 1 of 14 www parry co uk INSTRUCTIONS GAS SALAMANDER GRILL MODEL 7072 7073 Customer Information MODEL NUMBER ______________________ SERIAL NUMBER ______________________ PURCHASE DATE ________________...

Страница 2: ...NTENANCE INSTRUCTIONS CONVERSION INSTRUCTIONS TECHNICAL DETAILS PARTS LIST SPARES LIST WARRANTY INFORMATION MODEL 7072 7073 Gas Salamander Grill The products stated above are designed and built to com...

Страница 3: ...will cause burns if touched accidentally Therefore it is the responsibility of the supervisor or equivalent to provide SUITABLE PROTECTIVE CLOTHING for the user Users too should be aware of the regula...

Страница 4: ...UST be installed by a competent person in accordance with these and any other relevant regulations Users too should be aware of the regulations governing the use of gas appliances particularly with re...

Страница 5: ...ever is operating appliance is fully conversant with its operation and aware of dangers involved in incorrect operation and cleaning especially the danger of burns or scalds from the cooking medium an...

Страница 6: ...rills is a total of 20KG Operators should take care to systematically check and clean the cooking zone in particular the grill pan and receptacles before lighting to avoid the risk of fire It will be...

Страница 7: ...p to remove thermocouple assemble in reverse To replace ignition electrode Loosen the 2 screws on pilot ignition bracket and withdraw electrode disconnect lead To clean pilot injector Remove the 2 scr...

Страница 8: ...reverse order 5 1 LPG to Natural Remove side cover 4 screws Disconnect the gas feed at injector elbow Undo back nut holding back nut to burner Remove existing injector and replace with NAT injector su...

Страница 9: ...37mb 14 8 W G 5 43 KW 18527 Btu h G25 25mb 10 W G 5 6 KW 19107 Btu h GAS RATE NATURAL G20 0 5 M HR 17 95 FT HR BUTANE G30 0 397 kg HR 0 875 Lb HR PROPANE G31 0 391 kg HR 0 862 Lb HR G25 25mb 0 62 M HR...

Страница 10: ...OPANE G31 37mb 14 8 W G 7 03 KW 24000 Btu h G25 25mb 10 W G 7 22 KW GAS RATE NATURAL G20 0 633 M HR 22 35 FT HR BUTANE G30 0 522 Kg HR 1 149 Lb HR PROPANE G31 0 506 Kg HR 1 113 Lb HR AIR FLOW RATE FOR...

Страница 11: ...INSTRUCTION REF IN146 7 DATE 25 02 16 PAGE 11 of 14 www parry co uk EXPLODED VIEW...

Страница 12: ...CW nut INJECT119 LPG INJECT193 NAT INJECT135 LPG INJECT220 NAT 15a 8mm Olive OLVCOMPR8 OLVCOMPR8 16 Pilot Assembly PILOT3WAY PILOT3WAY 17 Electrode ELECTRODE ELECTRODE 18 Thermocouple THCP450MM THCP45...

Страница 13: ...used in a professional manor following the manufactures instructions and maintenance guide lines The warranty covers defects in the material and component failure only We are not liable for trading lo...

Страница 14: ...riddle plates Over use of lava rock on the chargrills recommended use by Parry 2kg only Faulty electrics eg customers plug socket plug wiring junction box fault wrong fuse Any damages caused by the cu...

Отзывы: