Installation & Operating Instructions for the 

F3513

   

 

   

                    Owner’s Installation ,Manual

 

 

 

 

 

 

   

All rights reserved.

Made in China

AFTER INSTRUCRION

 

MAKE THE ELECTRIC CONNECTIONS 

 

 

 

 

 

 

 

 

INSTALLING THE LIGHT KIT

 

 

 

WARNING:To avoid possible electrical shock, be sure electricity is turned off at the main fuse 
box  before wiring.

1. Insert the receiver into the mounting bracket with the flat side of the receiver facing the ceiling.  
2. Motor to Receiver Electrical Connections: Connect the Black wire from the fan to Black wire from 

the receiver. Connect the white wire from the fan to the white wire from the receiver. Connect the blue 

wire from the fan  to the Blue wire from the receive. Secure wire connections with the wire nuts provided. 
3. Receiver to House supply wires Electrical Connections: Connect the black(hot) wire from the ceiling 
to the black wire from the receiver.Connect the white(neutral) wire from the ceiling to the white wire from  
the Receiver. Secure the wire connections with the wire nuts provided.
4. Light kit to motor wires Electrical Connections: Connect the two white wires from light pan to the black 
and blue wires from fan. Secure the wire connections with the wire nuts provided.  

1.Remove the 7 

Light and Lampshade screws

 

preassembled from the  screws on the base 

plate. Connect white and blue wires from light kit and 

Lampshade 

to the white and blue wires 

from fan, using wire nuts provided. Attach the light fixture onto the base plate. Aligning the   
3 holes on the light fixture with and the 4 holes on the the 

Lampshade 

fixture with   

There are 7 screw holes in the bottom plate. Reinstall the 7 

Light and Lampshade 

 

screws

 

that were just removed. And tighten all nuts and screws securely. 

2. Install 3 X Max.25 watt bulbs (bulb not included)

WARNING: Over lamping the fan will result in the fan lights shutting down until 
the proper wattage of bulbs are installed.  Replace bulbs with the correct wattage 
bulbs, turn the power on.
WARNING: Do not replace bulb until it cools down.

WOBBLE

The fan blades have been adjusted in the factory to minimize any wobble
NOTE:CEILING FANS TEND TO MOVE DURING OPERATION DUE TO THE FACT THAT THEY ARE MOUNTED ON A RUBBER CROMMET. IF THE FAN WAS MOUNTED RIGIDLY TO THE CEILING, 
IT WOULD CAUSE EXCESS VIBRATION. MOVEMENT OF A FEW CENTIMENTERS IS QUITE ACCEPTABLE AND DOES NOT SUGGEST ANY PROBLEM

TO REDUCE THE FAN WOBBLE: PLEASE CHECK THAT ALL SCREWS WHICH SECURED THE MOUNTING BRACKET AND DOWNROD ARE SECURE.
BALANCING A WOBBLING CEILING FAN:
For your convenience, a Balancing Kit is included; please follow this procedure when balancing the fan:
1) Install fan without light dome before balancing the fan.
2) Define the base plate into four areas(point A,B,C&D). Use one weight from the balance kit to lightly stick on the edge of the base plate(Point A), if the wobble worsens, then take off the  
balance kit to lightly stick on the opposite side(Point B); if the wobble is worse,then go to the adjacent point C or D, if the wobble gets better, then securely stick on the weight  at this 

location on the base plate. 

3) After balancing the fan, assemble the light dome to the light base.

NOISE

When it is quiet(especially at night) you may hear occasional small noises. Slight power fluctuations and frequency signals superimposed in the electricity for off-peak hot water control,
may cause a change in fan motor noise. This is normal. Please allow a 24-hour “breaking-in” period, most noises associated with a new fan disappear during the time. The 

manufacturer’s warranty covers actual faults that may develop and NOT minor complaints such as hearing the motor run – All electric   

motors are audible to some extent.

CARE AND CLEANING

1. Periodic cleaning of your ceiling fan is the only maintenance required. Use a soft brush or lint ree cloth to avoid scratching the paint finish. Please make sure to turn off  electricity 
power before you clean your fan

2. Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.

3. Motor has permanently lubricated ball bearing. No need to oil

NOTE: MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU ATTEMPT ANY CLEANING OR REPAIRS. 

WARNING:SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER 

INSTALLING THE DOWNROD

CHANGING THE DOWNROD (OPTIONAL) 

                        

 

 

 

When hanging the Fan REMEMBER to turn off the power. Follow the steps below to hang your fan properly:

 

1)Remove the bolt, lock pin and set screws from the top of the housing 
2)Route wires exiting from the top of the fan motor through the bolt&pin , canopy and then through the ball / downrod.
3)Align the holes at the bottom of the downrod with the holes in the coupling on top of the top housing . 
4)Carefully insert the Bolt through the holes in the Coupling and downrod. Be careful not to jam the Bolt against the wiring inside the downrod. Insert the locking pin through the hole near the end 
   of the Bolt until it snaps into its locked position.
5)Tighten two set screws on top of the fan housing firmly

NOTE: Your fan comes with a 25cm downrod attached to the hanger ball.

  

In addition, a 10cm downrod has been provided to be used in case the 
ceiling is lower.In this case, perform the following steps for correct
installation: 
1. Remove the hanger ball from downrod by loosening the setscrew at the 

top of the downrod which holds the hanger ball to the downrod.
2. Slide the hanger ball down the downrod and remove the support pin.

3. Insert the support pin in the holes at the top of the 10cm downrod and 
slide the hanger ball up the 10cm downrod.  Make sure the support pin is 
properly seated in the grooves in the top of the hanger ball.
4.Tighten the set crews firmly . 

For Canadian installation and for USA fan and light kit combinations over 35 lbs, the safety cable must be installed into the house structure beams.  Make sure that when the safety cable is fully  
extended the lead wires are longer than the cable and no stress is placed on the lead wires. Note: If 

Installing The Secondary Support Safety Cable in the U.S., Do Not  

Remove Knockouts In The 

 

Outlet 

   

 

 Box.  

SAFETY CABLE INSTALLATION

Installation & Operating Instructions for the 

F3513

   

 

   

                    Owner’s Installation ,Manual

 

 

 

 

 

 

   

All rights reserved.

Made in China

INSTALLING THE FAN TO MOUNTING BRACKET ON CEILING

 

 

 

REMOTE CONTROL

Turn on the power and check the operation of the fan    

1– Fan Shutdown

2– Speed Controlle

3– Lamp Switch

 

1.Install ball end of downrod into mounting bracket opening. Align (engage) slot on ball with tab on mounting bracket. 

Warning: Failure to align slot on ball with tab may result in serious injury. 

2.Slide the canopy up to ceiling and align the keyhole slots on the canopy with the preassembled screws on the hanger

  bracket. Twist clockwise untill locks.Tighten two screws securely.   

WARNING:SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER 

WARNING:To avoid possible electrical dhock . be sure electricity is turned off at the main fuse box before wiring.

3.Attach the decorative canopy cover to the bottom of the canopy by pressing it until it locks.

USING YOUR CEILING FAN

4– Timer(2H,4H,8H)

Bolt

Coupling

Canopy

Downrod&

hanger ball

Coupling cover

Decorative

 Canopy  cover

Lock pin
Set screw

Base plate 

Lampshade