Parrot Uncle BBCF590 Скачать руководство пользователя страница 22

22

  

12. Light Kit LED Array Assembly Replacement

12.2

Rotate and remove the Shade counter-clockwise to 

expose the Light Kit Assembly (Figure 41).
Retain Shade for future reinstallation.

LIGHT KIT

ADAPTER/LIGHT

KIT ASSEMBLY

SHADE

ROTATE

COUNTER-CLOCKWISE

Figure 41

12.3

Loosened the two Light Kit Adapter 6-32 x 3/8” Truss 

Head Screws with Lockwashers located in the key hole 

slots.
Remove the remaining Light Kit Adapter 6-32 x 3/8” 

Truss Head Screws with Lockwasher (Figure 42). 

Retain for future use.
Rotate the Light Kit Assembly counter-clockwise to 

disengage the two 6-32 x 3/8” Truss Head Screws with 

Lockwashers in the key hole slots for removal of Light 

Kit Assembly. 

LIGHT KIT ASSEMBLY

REMOVE ONE 6-32 x 3/8" TRUSS

SCREW WITH LOCKWASHER

LOOSEN TWO 6-32 x 3/8"

TRUSS HEAD SCREWS

WITH LOCKWASHERS

ROTATE

COUNTER-CLOCKWISE

Figure 42

12.1

Disconnect electrical power to the branch circuit at the 

circuit breaker or fuse box before attempting to replace 

the Light Kit LED Array Assembly.

Tools Needed

One Phillips Head Screwdriver
One Stepladder

Turning off wall switch is not sufficient. To avoid 

possible electrical shock, be sure electricity is turned 

off at the main fuse box before wiring. All wiring 

must be in accordance with National and Local codes 

and the ceiling fan must be properly grounded as a 

precaution against possible electrical shock.

WARNING

!

To avoid possible electrical shock, be sure electricity 

is turned off at the main fuse box before wiring.

NOTE: If you are not sure if the outlet box is grounded, 

contact a licensed electrician for advice, as it must be 

grounded for safe operation.

WARNING

!

BP7513-3 CF590 Volta (EnSpFr) 210201.indd   22

2/1/21   1:55 PM

Содержание BBCF590

Страница 1: ...54 Ceiling Fan Owner s Manual BBCF590 CEILING FAN...

Страница 2: ...ough about electrical wiring have your fan installed by a licensed electrician NOTE This fan is suitable for use with solid state speed controls NOTE All set screws must be checked and re tightened wh...

Страница 3: ...iew illustration D F B C H I J L A G E K PACKAGE CONTENTS 1 3 9 2 7 4 5 6 8 Part Description Quantity A Fan Motor Assembly 1 B Hanger Bracket 1 C Hanger Ball 4 5 Downrod 1 D Ceiling Cover 1 E Motor Co...

Страница 4: ...a grounded electrical supply line of 120 Volts AC 60 Hz 15 Amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds If your fan is to replace an ex...

Страница 5: ...crews Reinstall the previously removed Screw Retighten the three Screws to securely assemble the Light Kit Adapter to the Motor Hub Spare 6 32 x 3 8 Truss Head Screws with Lockwasher in the parts bag...

Страница 6: ...3 5 Remove the Hanger Ball by loosening the Phillips Head Set Screw in the Hanger Ball until the Ball falls freely down the 4 5 Downrod Figure 5 Remove the Pin from the 4 5 Downrod then remove the Ha...

Страница 7: ...s in the Motor Coupler Install the Clevis Pin and secure with the Hairpin Clip Figure 8 The Clevis Pin must go through the Holes in the Motor Coupler It is critical that the Clevis Pin in the Motor Co...

Страница 8: ...HILLIPS HEAD SET SCREW Figure 11 3 11 Route the three 80 Motor Wires through the Hanger Ball Figure 11 Reinstall the Hanger Ball on the Downrod as follows Position the Pin through the two Holes in the...

Страница 9: ...ort of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING 4 1 Securely attach the Hanger Bracket to the Outlet Box using...

Страница 10: ...SEMBLY NOTE CEILING COVER SUPPL Y WIRES AND FAN WIRES OMITTED FOR CLARITY HANGER BRACKET HANGER BALL HANGER BALL GROOVE ANTI ROTATION TAB Figure 15 4 2 Carefully lift the partially assembled Ceiling F...

Страница 11: ...s Head Screws with Lockwashers in the Light Kit Adapter and loosen the remaining two Screws Figure 17 Retain the Screw and Lockwasher for future use Carefully tuck all the Wires into the Light Kit Ada...

Страница 12: ...SHADE ROTATE CLOCKWISE Figure 19 LIGHT KIT ASSEMBLY REINSTALL ONE 6 32 x 3 8 TRUSS HEAD SCREW WITH LOCKWASHER AND TIGHTEN SECURELY ENGAGE AND TIGHTEN THE TWO 6 32 x 3 8 TRUSS HEAD SCREWS WITH LOCKWASH...

Страница 13: ...aining two screws in the key hole slots Figure 21 Rotate the Light Kit Assembly counter clockwise for removal Replace the 6 32 x 3 8 Truss Head Screws with Lockwasher previously removed and tighten al...

Страница 14: ...ight Kit Adapter and turn the Plate clockwise until it stops Figure 23 NOTE The no light plate is equipped with an interference device that will not allow it to be installed if the light kit assembly...

Страница 15: ...N to the Supply White Wire neutral using the Wire Connector supplied in parts bag Figure 25 7 1 Connect the Green Grounding Wire from the Hanger Ball and the Green Grounding Wire from the Hanger Brack...

Страница 16: ...L IG H T AC IN N FAN MOTOR WHITE WIRE RECEIVER WHITE WIRE TO MOTOR N TO M O TO R L TO M OT OR N AC IN L Figure 27 7 4 Securely connect the Receiver White Wire TO MOTOR N to the Fan Motor White Wire u...

Страница 17: ...R BLUE WIRE TO LIGHT TO M OT O R N TO M O TO R L F O R LI G H T Figure 29 7 6 Securely connect the Receiver Blue Wire TO LIGHT to the Fan Motor Blue Wire using the Wire Connector supplied in parts bag...

Страница 18: ...the Ceiling Cover in place by sliding Lockwashers over the Threaded Studs and installing the two Knurled Knobs supplied in parts bag Figure 33 Tighten the Knurled Knobs securely until the Ceiling Cov...

Страница 19: ...over Your Receiver is equipped with a preset memory feature If the AC supply to the Receiver is powered through a Wall Switch when the Switch is turned OFF the Control will remember the Light Intensit...

Страница 20: ...s situations simply change the combination code in your Remote Control Transmitter CODE SWITCHES REMOTE CONTROL BATTERY COMPARTMENT COVER REMOTE CONTROL LEVERS ON 1 2 3 4 5 I Figure 36 NOTE If your Fa...

Страница 21: ...cure to Wall Figure 40 Slide the Wall Bracket Cover back down over the Screws TO INSTALL BRACKET TO WALL INSTALL THE TWO SCREWS SLIDE THE COVER DOWN WALL BRACKET SCREWS 2 COVER Figure 40 11 2 The Remo...

Страница 22: ...3 8 TRUSS SCREW WITH LOCKWASHER LOOSEN TWO 6 32 x 3 8 TRUSS HEAD SCREWS WITH LOCKWASHERS ROTATE COUNTER CLOCKWISE Figure 42 12 1 Disconnect electrical power to the branch circuit at the circuit breake...

Страница 23: ...e motor assembly The entire ceiling fan will have to be unwired and removed from the ceiling outlet box If you feel that you do not have enough electrical wiring knowledge or experience contact a lice...

Страница 24: ...tion AC IN N AC IN L RECEIVER TO M OT OR N TO M O TO R L FO R LI GH T OUTLET BOX WIRE CONNECTOR Figure 45 13 4 Carefully remove the Ceiling Fan hangerball downrod from the Hanger Bracket Place the Cei...

Страница 25: ...ation 13 8 Remove the two Set Screws using a Phillips Head Screwdriver from the Motor Coupler Figure 48 Retain both Set Screws for future reinstallation Remove the Downrod from the Motor Coupler and r...

Страница 26: ...Kit LED Driver Connector Figure 50 13 11 Remove the two Phillips Head Screws from the Old Light Kit LED Driver Figure 51 Retain the Screws for future reinstallation Gently pull up on the Old Light Kit...

Страница 27: ...sly removed in Step 13 9 Figure 54 UPPER MOTOR COVER REINSTALL UPPER MOTOR COVER SCREWS 6 Figure 54 13 15 Route the three Motor Wires through the 4 5 Downrod Figure 55 Re seat the Downrod in the Motor...

Страница 28: ...s 3 Steps 3 8 through 3 11 Figure 56 shows the beginning process 13 17 Rehang your Ceiling Fan per Section 4 Step 4 2 13 18 Rewire your Ceiling Fan per Section 7 Steps 7 1 through 7 7 13 19 Reinstall...

Страница 29: ...er ball downrod 2 Tighten the Set Screw in the hanger ball downrod assembly is loose assembly 3 Screws securing fan blades to 3 Check to be sure screws which attach the fan blades motor hub are loose...

Страница 30: ...erence to radio and TV reception The user is cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the user s authority to operate this equipme...

Страница 31: ......

Отзывы: