8
INSTALLATION
Electrical connection
Warning!
All electrical work must be carried out by a suitably qualified and authorized electrician. No alterations or
willful changes in the electricity supply should be carried out.
●
Before attempting the connection, check whether the voltage indicated on the rating plate corresponds to
the actual mains voltage.
●
Mains lead should be minimum 1.5m long.
570
20
547
595
558
564
600
560
40
●
Earthing wire should be installed in such manner to be the last one pulled out in case the safety relief
device of the mains lead should fail.
●
Mains lead behind the oven must be placed in such manner to avoid touching the back panel of the oven
because of the heat it develops during operation.
●
The cable of correct size rating must be used cable type H05VV-F 3×1.5m m
2
.
the grounding wire shall be longer
than the other wires.
Connection (by authorised electrician)
●
Using the screwdriver open the connector cover at the rear of the appliance. Release two locks located at
either side of the connector bottom.
●
Mains lead must be led through the relief safety device, protecting the mains lead cable from disconnection.
●
Tighten the relief device securely and close the connector cover.
220-240
V
50/60
Hz
Colour code
L=exterior live wires, usually coloured black, brown.
N=neutral