background image

 

 

Technical data 

 

Model: HO-1, HO-2, HO-7 

 
Model: HO-6

 

 

 

 
Gas input connection 

½” BSP 

Electricity supply 

AC 220-240v 50/60Hz 

Appliance type 

A1 

Appliance class 

class 3 (build in) 

Natural Gas (G20)  2kPa 

 

Product Code

 

 

No. of burners x Injector size 

 

Auxiliary  Semi-Rapid 

Rapid 

Wok 

HO-1-2S-2G 

1 x 0.72 

1 x 1.15 

HO-1-6W-3GW 

1 x 0.72 

2 x 0.97 

1 x 1.35 

HO-1-6S-3GW 

1 x 0.72 

2 x 0.97 

1 x 1.35 

HO-2-75S-4GW 

1 x 0.72 

2 x 0.97 

1 x 1.15 

1 x 1.35 

HO-2-6S-4G 

1 x 0.72 

2 x 0.97 

1 x 1.15 

HO-2-9S-4GW 

1 x 0.72 

2 x 0.97 

1 x 1.15 

1 x 1.35 

HO-7-6G-3GW 

1 x 0.72 

2 x 0.97 

1 x 1.35 

HO-7-9G-4GW 

1 x 0.72 

2 x 0.97 

1 x 1.15 

1 x 1.35 

 

 

Nominal Gas consumption per burner 

 

3.6 MJ/h 

6.3 MJ/h 

10.8 MJ/h 

13.7 

 MJ/h 

General Product LPG (G30/G31) 2.75kPa 

 

Product Code

 

 

No. of burners x Injector size 

 

Auxiliary  Semi-Rapid 

Rapid 

Wok 

HO-1-2S-2G 

1 x 0.50 

1 x 0.85 

HO-1-6W-3GW 

1 x 0.50 

2 x 0.65 

1 x 0.98 

HO-1-6S-3GW 

1 x 0.50 

2 x 0.65 

1 x 0.98 

HO-2-75S-4GW 

1 x 0.50 

2 x 0.65 

1 x 0.85 

1 x 0.98 

HO-2-6S-4G 

1 x 0.50 

2 x 0.65 

1 x 0.85 

HO-2-9S-4GW 

1 x 0.50 

2 x 0.65 

1 x 0.85 

1 x 0.98 

HO-7-6G-3GW 

1 x 0.50 

2 x 0.65 

1 x 0.98 

HO-7-9G-4GW 

1 x 0.50 

2 x 0.65 

1 x 0.85 

1 x 0.98 

 

 

Nominal Gas consumption per burner 

 

3.6 MJ/h 

6.3 MJ/h 

10.44 MJ/h 

13.7 

MJ/h 

General Product LPG (G30/G31) 2.75kPa 

 

Product Code

 

 

No. of burners x Injector size 

 

Auxiliary  Semi-Rapid 

Rapid 

Wok 

HO-6-6S-3GW 

1 x 0.50 

2 x 0.65 

(1 burner) 

5 x 0.5 

 

HO-6-77S-4GW 

1 x 0.50 

2 x 0.65 

1 x 0.80 

(1 burner) 

5 x 0.5 

 

HO-6-9S-4GW 

1 x 0.50 

2 x 0.65 

1 x 0.80 

(1 burner) 

5 x 0.5 

 

 

 

Nominal Gas consumption per burner 

 

3.6 MJ/h 

6.12 MJ/h 

9.0 MJ/h 

16.2 MJ/h 

Natural Gas (G20)  2kPa 

 

Product Code

 

 

No. of burners x Injector size 

 

Auxiliary  Semi-Rapid 

Rapid 

Wok 

HO-6-6S-3GW 

1 x 0.72 

2 x 0.97 

(1 burner) 

4 x 0.71 
1 x 0.80 

HO-6-77S-4GW 

1 x 0.72 

2 x 0.97 

1 x 1.23 

(1 burner) 

4 x 0.71 
1 x 0.80 

HO-6-9S-4GW 

1 x 0.72 

2 x 0.97 

1 x 1.23 

(1 burner) 

4 x 0.71 
1 x 0.80 

 

 

Nominal Gas consumption per burner 

 

3.6 MJ/h 

7.2 MJ/h 

10.8 MJ/h  16.2 MJ/h 

Содержание HO-1

Страница 1: ...1 HO 2 HO 6 HO 7 As part of Parmco Appliances commitment to improving and updating product ranges we reserve the right to alter change and update technical specifications and appearance attributes of...

Страница 2: ...by spills when cooking Any breakage or damage of glass items Any damage caused by non recommended product used for cleaning maintaining lubricating or similar Any aspect relating to the installation...

Страница 3: ...e take special note of all detailed technical information and installation instructions It is essential that you follow these instructions to ensure the safety and reliability of this appliance Furthe...

Страница 4: ...tchen units 13 Installation options 14 Guide to reading the instructions The following symbols will help you When reading the instructions Safety information Step by step instructions Suggestions and...

Страница 5: ...herwise contact your dealer before putting the appliance into operation The Manufacturer declines all responsibility in the case of failure to comply with accident prevention regulations Make sure tha...

Страница 6: ...nt Servicing work on this appliance must be carried out by a qualified technician only Always request the use of original spare parts Environmental protection advice All the materials used are environ...

Страница 7: ...Symbol present on versions with lighting integrated in the control knob Dual triple flame version no gas flow maximum gas flow from central burner minimum gas flow from central burner maximum gas flow...

Страница 8: ...attempts check that the burner cap and flame cap are correctly positioned To turn off the flame turn the control knob clockwise to the symbol Before removing pans from the burners always lower or turn...

Страница 9: ...er and a little liquid detergent Do not use the following products household detergents or bleaches soaped scouring pads not suitable for non stick utensils steel wool scouring pads stain removers for...

Страница 10: ...necessary repairs or adjustments must be carried out with the greatest care and attention For this reason we strongly advise you always to contact the Dealer who sold you the appliance or Parmco Serv...

Страница 11: ...0 98 HO 1 6S 3GW 1 x 0 50 2 x 0 65 0 1 x 0 98 HO 2 75S 4GW 1 x 0 50 2 x 0 65 1 x 0 85 1 x 0 98 HO 2 6S 4G 1 x 0 50 2 x 0 65 1 x 0 85 0 HO 2 9S 4GW 1 x 0 50 2 x 0 65 1 x 0 85 1 x 0 98 HO 7 6G 3GW 1 x...

Страница 12: ...through openings in the outside walls These openings must have an unobstructed cross section not less than 2m3 h for each kW of power see total power in kW on the appliance nameplate This opening mus...

Страница 13: ...shown on the plate Otherwise follow the instructions provided in the Adapting to di erent types of gas section For maximum e ciency and minimum consumption make sure that the gas supply pressure comp...

Страница 14: ...ppliance and the mains with at least 3mm between the contacts of suitable rating for the load while complying with the regulations in force The switch must not break contact in the yellow green earth...

Страница 15: ...he supply pipeline Setting the minimum level 1 Light the burner as already described 2 Turn the tap to the minimum flame position 3 Remove the control knobs 4 LPG to NG Use a thin blade screwdriver to...

Страница 16: ...n opening place the special gasket around the bottom edge of the hob It is important to fix this gasket evenly without gaps or overlapping in order to prevent liquid from seeping underneath the hob 1...

Страница 17: ...rical connections of the hob and oven must be made separately both for electrical reasons and for simplifying the removal of the oven through the front of the cabinet The distance must be at least 750...

Отзывы: