background image

13

14

c.  To select 15 Degrees – You will hear 3 short beeps. 

Move the throttle stick to center (between 1.4 and 

1.6ms). The controller will beep 2 times, indicating 

you have set the program selection or leave in 

full throttle for 5 seconds to advance to the next 

selection. 

d.  To select 20 Degrees – You will hear 4 short beeps. 

Move the throttle stick to center (between 1.4 and 

1.6ms). The controller will beep 2 times, indicating 

you have set the program selection or leave in 

full throttle for 5 seconds to advance to the next 

selection. 

e.  To select 25 Degrees – You will hear 5 short beeps. 

Move the throttle stick to center (between 1.4 and 

1.6ms). The controller will beep 2 times, indicating 

you have set the program selection or leave in 

full throttle for 5 seconds to advance to the first 

selection again.

Programming Menu 4 – Throttle Input Range 

(PWM)

The default setting is 1.2ms to 1.8ms and should work 

with most radio systems. This option allows for proper 

throttle input with many different radio systems. However, 

some radios have a wider output range, and may give 

a more linear response with the 1.1ms to 1.9ms range. 

If you feel there is too much “dead” area in the stick 

movement near full throttle, try adjusting the end points 

in your radio, or change to the wider input range. Be 

aware that if these settings are not correct, it may be 

impossible to arm the controller.

1.  Move the stick to center (between 1.4 and 1.6ms) 

for 5 seconds, and the controller will beep 4 times, 

indicating you are now in Menu 4. 

2.  Move the throttle stick to full throttle (>1.7ms) 

position to make changes to the Throttle Input 

Range programming. 

a.  To select 1.2ms to 1.8ms – You will hear 1 short 

beep. Move the throttle stick to center (between 

1.4 and 1.6ms). The controller will beep 2 times, 

indicating you have set the program selection or 

leave in full throttle for 5 seconds to advance to the 

next selection. 

b.  To select 1.1ms to 1.9ms – You will hear 2 short 

beeps. Move the throttle stick to center (between 

1.4 and 1.6ms). The controller will beep 2 times, 

indicating you have set the program selection or 

leave in full throttle for 5 seconds to advance to the 

first selection again.

Programming Menu 5 – Start-Up Rate 

The default setting is 0.25 seconds. The start-up rate 

is the time it takes to reach maximum motor speed. 

Changing the setting to 1 second can be useful with 

power-fragile gear boxes.

1.  Move the stick to center (between 1.4 and 1.6ms) 

for 5 seconds, and the controller will beep 5 times, 

indicating you are now in Menu 3. 

2.  Move the throttle stick to full throttle (>1.7ms) 

position to make changes to the Start-up Rate 

programming. 

a.  To select .25 second – You will hear 1 short beep. 

Move the throttle stick to center (between 1.4 and 

1.6ms). The controller will beep 2 times, indicating 

you have set the program selection or leave in 

full throttle for 5 seconds to advance to the next 

selection. 

b.  To select 1 second – You will hear 2 short beeps. 

Move the throttle stick to center (between 1.4 and 

1.6ms). The controller will beep 2 times, indicating 

you have set the program selection or leave in 

full throttle for 5 seconds to advance to the first 

selection again.

Programming Menu 6 – PWM Switching 

Frequency

The default setting is 8kHz, which should be acceptable 

for most motors. If you have a low or very low 

inductance motor and know you need to use a higher 

PWM Frequency (refer to the manual included with the 

motor), then you can change the setting. Otherwise, we 

recommend leaving the default setting.

1.  Move the stick to center (between 1.4 and 1.6ms) 

for 5 seconds, and  the controller will beep 6 times, 

indicating you are now in Menu 6. 

2.  Move the throttle stick to full throttle (>1.7ms) 

position to make changes to the PWM Switching 

Frequency programming. 

a.  To select 8kHz PWM Frequency – You will hear 

1 short beep. Move the throttle stick to center 

(between 1.4 and 1.6ms). The controller will beep 2 

times, indicating you have set the program selection 

or leave in full throttle for 5 seconds to advance to 

the next selection. 

IMPORTANT NOTE ABOUT 74% CUTOFF: This 

option will activate the soft cutoff at 74% of startup 

voltage or 9.2V, whichever is higher. For example, 

if your pack measures 16.8 volts at startup, then 

the soft cut will occur at 12.4 volts. The 

74% cutoff 

option will check the startup voltage every time you 

plug the battery into the controller, so beware of 

using partially charged packs, as the system cannot 

protect your Li-Po batteries if you are using the 74% 

cutoff and connect a partially charged pack. You will 

know your battery pack has reached soft auto cutoff 

when you hear the motor “pulse” repeatedly. We 

recommend you land your model as soon as you 

hear the motor pulse (indicating the pack voltage has 

dropped to the cutoff voltage level) to prevent over-

discharge of the Li-Po battery pack, and to prevent 

sudden power loss.

Programming Menu 2 – Brake Type

The default setting is Brake Off. This option gives you the 

choice to have the ESC stop the propeller during flight 

(Brake On) or allow it to windmill (Brake Off). Use the 

Brake On option for folding propellers.

1.  Move the stick to center (between 1.4 and 1.6ms) 

for 5 seconds, and the controller will beep 2 times, 

indicating you are now in Menu 2. 

2.  Move the throttle stick to full throttle (>1.7ms) 

position to  make changes to the Brake Type 

programming. 

a.  To select No Brake/Brake Off – You will hear 1 short 

beep. Move the throttle stick to center (between 

1.4 and 1.6ms). The controller will beep 2 times, 

indicating you have set the program selection or 

leave in full throttle for 5 seconds to advance to the 

next selection. 

b.  To select Soft Brake – You will hear 2 short beeps. 

Move the throttle stick to center (between 1.4 and 

1.6ms).  The controller will beep 2 times, indicating 

you have set the program selection or leave in 

full throttle for 5 seconds to advance to the next 

selection. 

c.  To select Medium Brake – You will hear 3 short 

beeps. Move the throttle stick to center (between 

1.4 and 1.6ms). The controller will beep 2 times, 

indicating you have set the program selection or 

leave in full throttle for 5 seconds to advance to the 

next selection. 

d.  To select Hard Brake – You will hear 4 short beeps. 

Move the throttle stick to center (between 1.4 and 

1.6ms). The controller will beep 2 times, indicating 

you have set the program selection or leave in 

full throttle for 5 seconds to advance to the first 

selection again.

Programming Menu 3 – Timing

The default setting is 15 degrees. As a general rule, 

lower pole count motors use lower timing and higher 

pole count motors use higher timing. Please refer to your 

motor instructions and specifications for an indication of 

the number of poles.

LowTimingAdvance

     Timing Degrees – 5 & 10 

Motor Poles – 2 to 4  

Expected Performance – Good balance of power and 

efficiency 

Motor Poles – 6 or more 

Expected Performance – Best efficiency and run time 

(lowest power)

StandardTimingAdvance

     Timing Degrees – 15 & 20 

Motor Poles – 6 to 12 

Expected Performance – Good balance of power and 

efficiency 

Motor Poles – 14 or more 

Expected Performance – Best efficiency and run time 

(lowest power)

HighTimingAdvance

     Timing Degrees – 25 

Motor Poles – 12  

Expected Performance – Highest power, less 

efficiency 

Motor Poles – 14 or more 

Expected Performance – Good balance of power and 

efficiency

1.  Move the stick to center (between 1.4 and 1.6ms) 

for 5 seconds, and the controller will beep 3 times, 

indicating you are now in Menu 3. 

2.  Move the throttle stick to full throttle (>1.7ms) 

position to make changes to the Timing 

programming.

a.  To select 5 Degrees – You will hear 1 short beep. 

Move the throttle stick to center (between 1.4 and 

1.6ms). The controller will beep 2 times, indicating 

you have set the program selection or leave in 

full throttle for 5 seconds to advance to the next 

selection. 

b.  To select 10 Degrees – You will hear 2 short beeps. 

Move the throttle stick to center (between 1.4 and 

1.6ms). The controller will beep 2 times, indicating 

you have set the program selection or leave in 

full throttle for 5 seconds to advance to the next 

selection. 

Содержание Bf-109G PNP

Страница 1: ...United Kingdom Horizon Hobby Deutschland GmbH Hamburger Strasse 10 25335 Elmshorn Germany ParkZone products are distributed exclusively by Horizon Hobby Inc DSM and DSM2 are trademarks or registered t...

Страница 2: ...toy Misuse of the plane can cause serious bodily harm and damage to property Therefore only an experienced RC pilot should fly it Note A 4 channel or greater radio is required for the Bf 109G PNP A 5...

Страница 3: ...exiting the sides of the fuselage and attach the clevis to the outermost hole on the control horn 6 Make sure both elevators are even to each other by adjusting the clevises Make any trim adjustments...

Страница 4: ...e stock Bf 109G motor Warning Use of the 3 bladed prop with the Apprentice motor will result in excess current and likely damage the motor Step 5 Step 6 Range Checking your Radio System After you have...

Страница 5: ...eron 5 8 up down 3 8 up down Elevator 5 8 up down 3 8 up down Rudder 3 4 left right 1 2 left right Mid Flap Full Flap Flap 1 2 inch 1 inch Ailerons if flaps are used High Rate Low Rate Ailerons 3 4 up...

Страница 6: ...cal than previous with ParkZone warbirds With the large scale 3 blade propeller there is a lot of torque that is most noticeable during takeoff The Bf 109G requires right rudder input during the takeo...

Страница 7: ...o center between 1 4 and 1 6ms The controller will beep 2 times indicating you have set the program selection or leave in full throttle for 5 seconds to advance to the first selection again Note The r...

Страница 8: ...you have set the program selection or leave in full throttle for 5 seconds to advance to the next selection IMPORTANT NOTE ABOUT 74 CUTOFF This option will activate the soft cutoff at 74 of startup v...

Страница 9: ...t PKZ4930 Swastika Decal for Tail Not available in all territories SPMR5500 DX5e Mode 2 Full Range Transmitter SPMR6600 DX6i Mode 2 Full Range Transmitter Recommended Touch up Paints Floquil GRAUGRUN...

Страница 10: ...r a list of the included items method of payment for any non warranty expenses and a brief summary of the problem Your original sales receipt must also be included for warranty consideration Be sure y...

Страница 11: ...vironment For more information about where you can drop off your waste equipment for recycling please contact your local city office your household waste disposal service or where you purchased the pr...

Страница 12: ...21 22...

Отзывы: