21
© 2014 - 2024 Parktron Technology Ltd.
2.3. DC power outputs of terminal device & signal inputs:
2.3.1. Wiring contacts for fixed functions:
CN5
– Spare DC power output pairs; voltage available: 12V and 24V, Maximum load
1A for each output. (Refer to the drawing in section 2.2.1 for CN5 location)
CN7
- Signal inputs: (Refer to the drawing in section 2.2.1 for CN7 location)
CN
number
Connector-Contact
Name
Function description
CN7
A5
Spare input
CN7
A6
Spare input
CN7
A7
Spare input
CN7
DB25-3/25
& B2
Accept barrier gate open signal from
Exit-POS
(pay-at-exit
Cashier Station) or other access control system (building
access control, license plate recognition, remote access
system).