Parkside PSB 1050 A1 -  3 Скачать руководство пользователя страница 6

GB/IE/CY

   

Included items

1 2-Speed hammer drill PSB 1050 A1
1 Auxiliary handle
1 Dust extraction device
1 Angle adaptor
1 Reducer piece
1 Depth stop
1 Carry case
1 Operating instructions

   

Technical data

Nom. voltage: 

230 V~ 50 Hz

Rated power: 

1050 W

No-load  
rotational speed: 

 1st gear 0 - 1450 min

-1

 

2nd  gear  0 - 3400 min

-1

Chuck capacity: 

max. 13 mm

Recommended areas of operations
Drilling in steel: 

max. ø 13 mm

Drilling in wood: 

max. ø 40 mm

Percussion drilling 
into cement: 

max. ø 16 mm

Screwing: max. 

ø 

mm

Protection class: 

II / 

Noise and vibration data:

Measured values for noise are determined in accor-
dance with EN 60745. The A-weighted noise level 
of the electrical power tool are typically:
Sound pressure level:  98.5 dB(A)
Sound power level:   109.5 dB(A)
Uncertainty K: 

3 dB

  Wear ear protection!

Impact drilling in concrete:

max. Vibration emission value 
a

h, ID

=  14.826 m / s

2

 

Uncertainty  
K  =  1.5 m / s

2

 

Drilling in metal:

max. Vibration emission value 
a

h, D

=  3.745 m / s

2

Uncertainty  
K  =  1.5 m / s

2

WARNING!

 The vibration level given in these 

instructions has been measured in accordance with 
a standardised measurement procedure specified 
in EN 60745 and can be used to compare devices.
Different uses of the device give rise to different vibra-
tion levels and in many cases they may exceed the 
values given in these instructions. It is easy to underes-
timate the vibration load if the electrical power tool 
is used regularly in particular circumstances.

Note: 

If you wish to make an accurate assessment 

of the vibration loads experienced during a particu-
lar period of working, you should also take into 
account the intervening periods of time when the 
device is switched off or is running but is not actual-
ly in use. This can result in a much lower vibration 
load over the whole of the period of working.

 General safety advice for 
electrical power tools

WARNING!

 

Read all the safety advice 

and instructions!

 

Failure to observe the safety 

advice and instructions may result in electric shock, 
fire and / or serious injury.

Keep all the safety advice and instructions 
in a safe place for future reference!

The term “electrical tool” used in the safety advice 
refers to electrical tools powered by mains electrici-
ty (by means of a mains lead) and electrical tools 
powered by rechargeable batteries (without a 
mains lead).

1.

 

Workplace safety

a)  

Keep your working area clean and 
well lit.

 

Untidy or poorly lit working areas 

can lead to accidents.

Introduction / General safety advice for electrical power tools

Содержание PSB 1050 A1 - 3

Страница 1: ...PSB 1050 A1 2 2 SPEED HAMMER DRILL Operation and Safety Notes Translation of original operation manual 3 2 GANG SCHLAGBOHRMASCHINE Bedienungs und Sicherheitshinweise Originalbetriebsanleitung...

Страница 2: ...herheitshinweise Seite 25 Before reading unfold the page containing the illustrations and familiarise yourself with all functions of the device Klappen Sie vor dem Lesen die Seite mit den Abbildungen...

Страница 3: ...8 9 11 4 5 7 10 B C D E A 2 6 8 3 1 F 11 12 9 10 13 12...

Страница 4: ...sories attachments Page 10 Before first use Mounting or adjusting the additional handle Page 10 Using the depth stop Page 10 Inserting tools Page 10 Fitting using the dust extraction device Page 11 Fi...

Страница 5: ...ty for loss or damage arising from improper use The device is not intended for commercial use Features 1 Quick action drill chuck with lock 2 Changeover switch drill percussion drill 3 Locking button...

Страница 6: ...compare devices Di erent uses of the device give rise to di erent vibra tion levels and in many cases they may exceed the values given in these instructions It is easy to underes timate the vibration...

Страница 7: ...for protection if operating the electrical power tool in a moist environment is unavoidable The use of an RCD reduces the risk of electric shock 3 Personal safety a Remain alert at all times watch wha...

Страница 8: ...e the electrical power tool accesso ries inserted tools etc in accordance with these instructions and advice and the stipulations drawn up for this par ticular type of device In doing this take into a...

Страница 9: ...he plug out of the mains socket before carrying out any work on the device Mounting or adjusting the additional handle NOTE For reasons of safety you may only use this appliance with a properly mounte...

Страница 10: ...vice 11 up to a drill size of 13 mm If it is necessary to use the reducer piece 13 push the reducer piece into the adapter for ex ternal vacuum extraction 12 To dismantle proceed in reverse order to w...

Страница 11: ...tenance free Do not allow any liquids to enter the device Use a cloth to clean the device Clean the device after you have nished using it Do not under any circumstances use petrol or strong solvents C...

Страница 12: ...e disposed of at a local recycling centre Do not dispose of electrical power tools with the household rubbish In accordance with European Directive 2002 96 EC worn out electrical power tools must be c...

Страница 13: ...14...

Страница 14: ...15 GR CY E 16 16 17 17 17 1 18 2 18 3 18 4 19 20 20 20 21 21 21 21 22 22 22 22 23 23 23 23 24 24...

Страница 15: ...16 GR CY 2 PSB 1050 A1 E B F 1 2 3 4 5 E V Volt W Watt II...

Страница 16: ...6 7 8 9 10 11 12 13 1 2 PSB 1050 A1 1 1 1 1 1 1 1 230V 50Hz 1050W 1 0 1450 2 0 3400 13mm 13mm 40mm 16mm 8mm II 60745 A 98 5dB A 109 5dB A K 3dB ah ID 14 826m s2 K 1 5m s2 ah D 3 745m s2 K 1 5m s2 EN...

Страница 17: ...18 GR CY a 1 2 3...

Страница 18: ...19 GR CY 4...

Страница 19: ...20 GR CY...

Страница 20: ...21 GR CY 10 9 10 9 10 9 8 9 Made in Germany 1 4 bit bit 2 11 10 8 9...

Страница 21: ...22 GR CY 8 11 9 9 11 10 9 12 F 11 13mm 13 12 4 4 4 3 4 5 1 2 4 4 6 4...

Страница 22: ...23 GR CY 6 6 2 2 2 11 3...

Страница 23: ...ernass com 2002 96 EC Komperna GmbH Felix Becker Burgstr 21 D 44867 Bochum 2006 42 EC 2006 95 EC 2004 108 EC EN 55014 1 2006 EN 55014 2 A2 2008 EN 61000 3 2 2006 EN 61000 3 3 2008 EN 60745 1 2009 EN 6...

Страница 24: ...Schlagbohrmaschinen Seite 29 Achtung Leitungen Seite 30 Originalzubeh r zusatzger te Seite 30 Vor der Inbetriebnahme Zusatz Handgriff montieren verstellen Seite 30 Tiefenanschlag verwenden Seite 30 We...

Страница 25: ...cht f r den gewerblichen Einsatz bestimmt Ausstattung 1 Schnellspannbohrfutter mit Verriegelung 2 Umschalter Bohren Schlagbohren 3 Feststelltaste f r EIN AUS Schalter 4 EIN AUS Schalter 5 Stellrad Dre...

Страница 26: ...r den Ger tevergleich verwendet werden Der Schwingungspegel wird sich entsprechend dem Einsatz des Elektrowerkzeugs ver ndern und kann in manchen F llen ber dem in diesen Anweisungen angegebenen Wert...

Страница 27: ...r den Au enbereich zugelassen sind Die Anwendung eines f r den Au enbereich geeigneten Verl ngerungskabels verringert das Risiko eines elektrischen Schlages f Wenn der Betrieb des Elektrowerk zeuges i...

Страница 28: ...k zeuge sind gef hrlich wenn sie von unerfahrenen Personen benutzt werden e P egen Sie Elektrowerkzeuge mit Sorgfalt Kontrollieren Sie ob beweg liche Teile einwandfrei funktionieren und nicht klemmen...

Страница 29: ...ug kann sich verhaken und zum Verlust der Kontrolle ber das Elektrowerkzeug f hren Achtung Leitungen GEFAHR Vergewissern Sie sich dass Sie nicht auf Strom Gas oder Wasserleitungen sto en wenn Sie mit...

Страница 30: ...ag 8 zuvor entnommen wurde L sen Sie ggf die Fl gelschraube 9 gegen den Uhrzei gersinn und entnehmen Sie den Tiefenanschlag 8 Stecken Sie ihn nach Montage der Absaugvorrichtung 11 wieder auf und ziehe...

Страница 31: ...gel Beton und Gestein geeignet Hinweis Schalten Sie den Umschalter Bohren Schlagbohren 2 nur beim Stillstand des Ger tes um Bohren Schieben Sie den Umschalter 2 nach rechts auf die Position Schlagbohr...

Страница 32: ...ird durch die Gew hrleistung nicht verl ngert Dies gilt auch f r ersetzte und reparierte Teile Eventuell schon beim Kauf vorhandene Sch den und M ngel m ssen sofort nach dem Auspacken gemeldet werden...

Страница 33: ...agnetische Vertr glichkeit 2004 108 EC angewandte harmonisierte Normen EN 55014 1 2006 EN 55014 2 A2 2008 EN 61000 3 2 2006 EN 61000 3 3 2008 EN 60745 1 2009 EN 60745 2 1 A12 2009 IEC 62233 2005 EN 62...

Страница 34: ...IAN 49374 KOMPERNASS GMBH Burgstra e 21 D 44867 Bochum by ORFGEN Marketing Last Information Update Stand der Informationen 06 2010 Ident No PSB 1050 A1 062010 3 3...

Отзывы: