Troubleshooting
In the event of an accident or malfunction, remove the battery from the device
immediately! Failure to comply may result in injuries from cuts.
Problem
Possible cause
Error correction
Appliance does not
start
Battery (1) discharged
Recharge battery (1)
(Observe the separate operating
instructions for the rechargeable
battery and charger)
Battery (1) not in
Insert battery (1)
(Observe the separate operating
instructions for the rechargeable
battery and charger)
On/off switch (18) is broken
Repair by Customer Care
Motor faulty
Engine is slower
and stops
Device is overloaded through
workpiece
Reduce the pressure
Increase rotation speed
Workpiece unsuitable
The milling is not
straight
Parallel stop (22) not
inserted
Mounting the parallel stop.
The milled work-
piece has burn
marks
Unsuitable or blunt cutter
Adjust cutting depth
Cutting depth is set too large
Use the step stop to mill in multi-
ple steps
The fringes of the
milled part tear off,
there are grooves
and uneven parts
in the milling
Cutter is worn out and dull
Change the cutter
Cutter blades are damaged
Change the cutter
Dust is not being
sucked off
Vacuum is not switched on
Turn on vacuum before milling
Suction hose or suction adapt-
er (21) is clogged
Remove clogging