13
GB
IE
NI
CY
Trouble shooting
Problem
Possible cause
Fault correction
Device does not start
Mains voltage is not present
Check plug socket, cable, line,
plug and fuse, where appropri-
ate, repair through electrical
specialist
Defective on/off switch
(
3)
Repair through customer service
Worn carbon brushes
Defective motor
Low or lack of suction
Hose system
(
13/14) or
jets
(
18/20) blocked
Remove obstructions and block-
ages
Suction pipe
(
12) assem-
bled incorrectly
Assemble suction pipe correctly
Container
(
6) open
Close container
Container
(
6) full
Empty container
Filter
(
15/16/17) full or
clogged
Empty, clean or replace ilter
Float in ilter basket (
21)
incorrectly positioned (e.g.
due to jerky movements)
Switch off the equipment so the
ball drops then switch on again
Float in the ilter basket
(
21) faulty
Repair by Customer Care
Float does not switch
the appliance off
Float in the ilter basket
(
21) does not move
Release loat
Float in the ilter basket
(
21) faulty
Repair by Customer Care
Dust or dirt is blow
out of the device
Filter (
15/16/17) is not
or not correctly assembled
Use missing ilters or check the
correct position of the ilter