14. Troubleshooting
Fault
Possible cause
Remedy
The compressor does not
start.
No supply voltage.
Insufficient supply voltage.
Outside temperature is too low.
Motor is overheated.
Check the supply voltage, the power plug and the socket-
outlet.
Make sure that the extension cable is not too long. Use
an extension cable with large enough wires.
Never operate with an outside temperature of below
+5° C.
Allow the motor to cool down. If necessary, remedy the
cause of the overheating.
The compressor starts but
there is no pressure.
The non-return valve (19) leaks.
The seals are damaged.
The drain plug for condensation water (10) leaks.
Contact your local service centre. Every attempt to carry
out a repair, can be dangerous if it is not done by skilled
personnel.
Check the seals and have any damaged seals replaced
by a service center.
Tighten the screw by hand. Check the seal on the screw
and replace if necessary.
The compressor starts,
pressure is shown on the
pressure gauge, but the
tools do not start.
The hose connections have a leak.
A quick-lock coupling has a leak.
Insufficient pressure set on the pressure regulator
(5).
Check the compressed air hose and tools and replace if
necessary.
Contact your local service centre. Every attempt to carry
out a repair, can be dangerous if it is not done by skilled
personnel.
Increase the set pressure with the pressure regulator.