9.3 Safety valve (Figure 2)

The safety valve (19) has been set for the highest 
permitted pressure of the pressure vessel. It is 
prohibited to adjust the safety valve or remove its 
seal. Actuate the safety valve from time to time to 
ensure that it works when required. Pull the ring 
with suffi cient force until you can hear the com-
pressed air being released. Then release the ring 
again.

9.4 Checking the oil level at regular inter-

vals (Figure 11)

Place the compressor on a level and straight 
surface. The oil level must be between the two 
marks MAX and MIN on the oil dipstick (16). Oil 
change: we recommend SAE 15W 40 or equiva-
lent. The original oil fi lling must be changed after 
100 hours in operation; thereafter the oil must be 
drained and replaced with new oil after every 
300 hours in operation.

9.5 Changing the oil (Figure 1,10, 11)

Switch off the motor and pull the mains plug out 
of the socket. After releasing any air pressure (see 
9.7.1) you can unscrew the oil drain screw (18) 
from the compressor pump (13). To prevent the oil 
from running out in an uncontrolled manner, hold 
a small metal chute under the opening and collect 
the oil in a container. If the oil does not drain out 
completely, we recommend tilting the compressor 
slightly. When the oil has drained out, refi t the oil 
drain screw (18).

Dispose of the old oil at a drop-off point 
for old oil.

To fi ll in the correct quantity of oil, make sure that 
the compressor stands on an even surface. Fill 
new oil through the oil fi ller opening (21) until it 
comes up to the maximum level. Check the oil 
level by inserting the dipstick. Do not exceed 
the maximum fi lling quantity. Overfi lling the 
equipment may result in damage. Reinsert the oil 
sealing plug (16) into the oil fi ller opening (21).

9.6 Cleaning the intake fi lter 

(Fig. 2, 3, 12) 

The intake fi lters (15) prevent the drawing in 
of dust and dirt. It is essential to clean these 
fi lters after at least every 300 hours in opera-
tion. A clogged intake fi lter will decrease the 
compressor’s performance dramatically.
Remove the intake fi lters from the equipment by 
unscrewing them. The fi lter housing (D) is plugged 
on the fi lter cover (C) and can be removed by ap-
plying slight pressure to the fi lter cover. Carefully 
tap out the air fi lters (F), the fi lter cover and the 
fi lter housing. Then blow out these parts with com-
pressed air (approx. 3 bar) and reinstall in reverse 
order. The fi lter cover and the fi lter housing have 
different latching positions. When you assemble 
the intake fi lter, make sure that the intake opening 
faces down.

9.7 Storage

 Important!

Pull out the mains plug and ventilate the 
equipment and all connected pneumatic 
tools (see 9.7.1). Switch off the compres-
sor and make sure that it is secured in 
such a way that it cannot be started up 
again by any unauthorized person.

 Important!

Store the compressor only in a dry lo-
cation which is not accessible to unau-
thorized persons. Always store upright, 
never tilted! Oil may leak out!

9.7.1 Releasing excess pressure

Release the excess pressure by switching off the 
compressor and using the compressed air which 
is still left in the pressure vessel, e.g. with a com-
pressed air tool running in idle mode or with a 
blow-out pistol.

Anl_4010166.indb   14

Anl_4010166.indb   14

25.03.13   16:01

25.03.13   16:01

Содержание PKO 400 B2

Страница 1: ...ration and Safety Notes Original operating instructions K O COMPRESSOR PKO 400 B2 F A C KOMPRESSOR Bedienungs und Sicherheitshinweise Originalbetriebsanleitung Anl_4010166 indb 1 Anl_4010166 indb 1 25...

Страница 2: ...the device F A C Klappen Sie vor dem Lesen die Seite mit den Abbildungen aus und machen Sie sich anschlie end mit allen Funktionen des Ger tes vertraut GB IE Operation and Safety Notes Page 6 DE AT C...

Страница 3: ...3 1 2 9 11 2 7 8 3 G 3 4 5 6 8 10 13 14 17 3 1 15 15 19 4 20 21 12 16 18 Anl_4010166 indb 3 Anl_4010166 indb 3 25 03 13 16 00 25 03 13 16 00...

Страница 4: ...4 4 7 8 6 29 22 23 24 26 8 27 23 28 11 25 26 15 28 27 23 5 24 23 11 8 15 29 25 22 B Anl_4010166 indb 4 Anl_4010166 indb 4 25 03 13 16 01 25 03 13 16 01...

Страница 5: ...5 9 10 11 12 A max min 15 16 18 16 D F C 15 21 15 Anl_4010166 indb 5 Anl_4010166 indb 5 25 03 13 16 01 25 03 13 16 01...

Страница 6: ...n 8 2 Safety regulations 8 3 Layout and items supplied 10 4 Proper use 1 1 5 Technical data 1 1 6 Before starting the equipment 12 7 Assembly and starting 12 8 Replacing the power cable 13 9 Cleaning...

Страница 7: ...ay start up without warning Caution Before using for the rst time check the oil level and replace the oil sealing plug Important Do not open the stopcock pressure regulator until the air hose is conne...

Страница 8: ...away Do not allow other persons to touch the com pressor or cable keep them away from your work area Keep your compressor in a safe place When unused the compressor must be stored in a dry locked room...

Страница 9: ...for the maximum permissi ble operating pressure of the compressor For pressures above 7 bar it is recommended to use an air line with a safety cable 2 2 Safety instructions for working with compressed...

Страница 10: ...lose these safety instructions 3 Layout and items supplied 3 1 Layout 1 Transport handle 2 Pressure switch 3 Pressure regulator 4 Quick lock coupling regulated compressed air 5 Pressure gauge for rea...

Страница 11: ...signed for use in commercial trade or industrial applications Our warranty will be voided if the machine is used in commercial trade or industrial businesses or for equivalent purposes 5 Technical dat...

Страница 12: ...size 16 mm not in cluded 7 1 Fitting the wheels 11 Fit the supplied wheels as shown in Figure 5 7 2 Fitting the supporting feet 8 Fit the supplied supporting feet as shown in Figure 6 7 3 Fitting the...

Страница 13: ...essure We recommend that you clean the equipment immediately after you use it Clean the equipment regularly with a damp cloth and some soft soap Do not use cleaning agents or solvents these may be agg...

Страница 14: ...s up to the maximum level Check the oil level by inserting the dipstick Do not exceed the maximum lling quantity Over lling the equipment may result in damage Reinsert the oil sealing plug 16 into the...

Страница 15: ...it and its accessories are made of various types of material such as metal and plastic De fective components must be disposed of as spe cial waste Ask your dealer or your local council For EU countrie...

Страница 16: ...valve leaks 2 The seals are damaged 3 The drain plug for condensation water 9 leaks 1 Have a service center replace the non return valve 2 Check the seals and have any da maged seals replaced by a ser...

Страница 17: ...na podstawie dyrektywy WE BG LV paskaidro du atbilst bu ES direkt vai un standartiem LT apib dina atitikim EU reikalavimams ir prek s normoms RO declar urm toarea conformitate conform directivei UE i...

Страница 18: ...pped and normal wear resulting from proper operation of the device This applies in particular to rechargeable batteries for which we nevertheless issue a guarantee period of 12 months The guarantee is...

Страница 19: ...itshinweise 21 3 Ger tebeschreibung und Lieferumfang 23 4 Bestimmungsgem e Verwendung 24 5 Technische Daten 24 6 Vor Inbetriebnahme 25 7 Montage und Inbetriebnahme 25 8 Austausch der Netzanschlussleit...

Страница 20: ...ferngesteuert und darf ohne Warnung anlaufen Achtung Vor Erstinbetriebnahme lstand berpr fen und lverschlussstopfen austauschen Achtung Den Hahn Druckregler nicht ffnen bevor der Luftschlauch angeschl...

Страница 21: ...hr Sch tzen Sie sich vor elektrischem Schlag Vermeiden Sie K rperber hrung mit geerde ten Teilen zum Beispiel Rohren Heizk rpern Herden K hlschr nken Halten Sie Kinder fern Lassen Sie andere Personen...

Страница 22: ...falls k nnen Unf lle f r den Betreiber entste hen Ger usch Bei Verwendung des Kompressors Geh r schutz tragen Austausch der Anschlussleitung Wenn die Anschlussleitung besch digt wird muss sie vom Hers...

Страница 23: ...n wie Testbenzin Butylalkohol und Methylenchlorid Diese Medien zerst ren den Druckschlauch 2 4 Betrieb von Druckbeh ltern Wer einen Druckbeh lter betreibt hat die sen in einem ordnungsgem en Zustand z...

Страница 24: ...h des Druckluftwerkzeugs bei dessen Betriebsdruck Die Maschine darf nur nach ihrer Bestimmung verwendet werden Jede weitere dar ber hinaus gehende Verwendung ist nicht bestimmungsge m F r daraus hervo...

Страница 25: ...Montieren Sie die beiliegenden R der wie in Bild 5 dargestellt 7 2 Montage der Standf e 8 Montieren Sie die beiliegenden Standf e wie in Bild 6 dargestellt 7 3 Montage der Luft lter 15 Entfernen Sie...

Страница 26: ...s Sie das Ger t direkt nach jeder Benutzung reinigen Reinigen Sie das Ger t regelm ig mit einem feuchten Tuch und etwas Schmierseife Ver wenden Sie keine Reinigungs oder L sungs mittel diese k nnten d...

Страница 27: ...is der lstand die maximale F llmenge erreicht Pr fen Sie den lstand durch Einstecken des lmessstabes berschreiten Sie nicht die maximale F llmenge Eine berf llung kann einen Ger teschaden zur Folge ha...

Страница 28: ...n dem Rohstoffkreislauf zur ckge f hrt werden Das Ger t und dessen Zubeh r bestehen aus verschiedenen Materialien wie z B Metall und Kunststoffe F hren Sie defekte Bau teile der Sonderm llentsorgung z...

Страница 29: ...ruck 1 R ckschlagventil undicht 2 Dichtungen kaputt 3 Ablass Schraube f r Kondenswas ser 9 undicht 1 R ckschlagventil austauschen 2 Dichtungen berpr fen kaputte Dichtungen bei einer Fachwerkstatt erse...

Страница 30: ...na podstawie dyrektywy WE BG LV paskaidro du atbilst bu ES direkt vai un standartiem LT apib dina atitikim EU reikalavimams ir prek s normoms RO declar urm toarea conformitate conform directivei UE i...

Страница 31: ...dung oder Fremdeinwirkungen wie z B Sch den durch Herunter fallen sowie durch verwendungsgem en blichen Verschlei ausgeschlossen Dies gilt insbesondere f r Akkus auf die wir dennoch eine Garantiezeit...

Страница 32: ...32 Anl_4010166 indb 32 Anl_4010166 indb 32 25 03 13 16 01 25 03 13 16 01...

Страница 33: ...33 Anl_4010166 indb 33 Anl_4010166 indb 33 25 03 13 16 01 25 03 13 16 01...

Страница 34: ...2 Einhell Germany AG Wiesenweg 22 D 94405 Landau Isar IAN 89566 Last Information Update Stand der Informationen 04 2013 Ident No 40 101 66 042013 6 6 Anl_4010166 indb 34 Anl_4010166 indb 34 25 03 13 1...

Отзывы: