![Parkside PHGA 1300 A1 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/parkside/phga-1300-a1/phga-1300-a1_operating-and-safety-instructions-manual_3864121016.webp)
10
GB/IE
16. Troubleshooting
Note:
When returning the device for repair, please ensure for safety reasons that it is empty and dry when it is sent to the service centre.
Fault
Possible cause
Remedy
Motor does not start or
suddenly stops during
operation
No mains voltage
Check mains voltage
Electrical interruption
Have the garden pump and domestic waterworks checked
in a specialist workshop.
Pump impeller jammed and thermal sensor
has tripped
Disconnect the garden pump and domestic waterworks
from the power supply, dismantle and clean the hoses and
connections
Garden pump and domestic
waterworks does not suck
Suction valve not in the water
Put the suction valve in the water
Garden pump and domestic waterworks not
filled with pumped liquid
Fill garden pump and domestic waterworks with water
Garden pump and domestic waterworks
sucks in air at a connection point
Seal the suction-side connections airtight
Leaky or damaged suction hose
Check suction hose for damages and seal airtight
Pre-filter locking screw leaks
Check seal and replace it if necessary - tighten hand-tight
Max. suction height exceeded
Check suction height
Waiting time was not maintained
Turn on the garden pump and domestic waterworks and
wait until it pumps water
Air cannot escape because the pressure
hose is closed or there is residual water in
the pressure hose
Open the consumer which is connected to the pressure line
(z. B. nozzles, showers, etc.), or empty the pressure line or
remove is from the garden pump and domestic waterworks
when pumping.
Pre-filter or suction line clogged
Clean pre-filter or suction line
Motor runs, but the flow
rate or pressure suddenly
drops
Suction height too high
Check suction height
Water level dropping rapidly
Position suction valve lower
Garden pump and domestic waterworks
performance reduces due to hazardous
substances
Clean garden pump and domestic waterworks and
replace worn parts
Pre-filter or suction line clogged
Clean pre-filter or suction line
Suction-side leaks
Seal suction-side
Flow sensor impeller blocks
Have the garden pump and domestic waterworks checked
in a specialist workshop.
Thermal sensor shuts off the
garden pump and domestic
waterworks
Motor overloaded, friction too high due to
foreign bodies
Dismantle garden pump and domestic waterworks and
clean, avoid suctioning foreign bodies
Garden pump and domestic
waterworks does not switch
off in automatic mode
Flow sensor impeller worn or defective
Have the garden pump and domestic waterworks checked
in a specialist workshop.
Flow sensor defective
Have the garden pump and domestic waterworks checked
in a specialist workshop.
In automatic mode, the
garden pump and domestic
waterworks unintentionally
switches on again after it
has been switched off
Non-return valve defective
Have the garden pump and domestic waterworks checked
in a specialist workshop.
LCD display doesn’t switch
on
No mains voltage
Check mains voltage
LCD display defective
Have the garden pump and domestic waterworks checked
in a specialist workshop.