z
Inserting the flux-cored
wire
Always unplug the mains
plug from the mains socket prior to each
maintenance task or preparatory work in order
to prevent the risk of an electric shock, injury
or damage.
Please note:
Different welding wires will
be needed depending on the application.
Welding wires with a diameter of
0.6 - 1.0 mm can be used with this device.
Feed roll, welding nozzle and wire cross-
section must be compatible with one another.
The device is suitable for wire reels weighing
up to maximum 1000 g.
Unlock and open the cover of the wire
feed unit
1
by raising the threaded rod
along the elongated hole.
Unlock the roller unit by turning the roller
mount
29
anti-clockwise (see Fig. F).
Pull the roller mount
29
off the shaft
(see Fig. F).
Please note:
Make sure that the end of the
wire does not come loose and cause the roll
to roll out on its own. The end of the wire
may not be released until during assembly.
Completely unpack the flux-cored wire
welding reel
17
, so that it can unrolled
without difficulty. Do not release the wire
end yet (see Fig. G).
Place the wire reel on the shaft. Make
sure that the roll unwinds on the side of
the
31
wire feed guide (see Fig. G).
Place the roll mount
29
back on and
lock it by pressing and turning it clock-
wise (see Fig. G).
Undo the adjustment screw
27
and swing
it upwards (see Fig. H).
Turn the thrust roller unit
28
to the side
(see Fig. I).
Loosen the feed roll holder
30
by turning
it anti-clockwise and pull it upwards and
off (see Fig. J).
On the top of the feed roll
19
, check
whether the appropriate wire thickness is
indicated. If necessary, the feed roll has
to be turned over or replaced. The sup-
plied welding wire (Ø 0.9 mm) must be
used in the feed roll
19
with the specified
wire thickness of Ø 0.9 mm. The wire
must be positioned in the upper groove!
Erect the feed roll holder
30
again and
screw clockwise direction.
Remove the torch nozzle
9
by turning
it clockwise (see Fig. K).
Unscrew the welding
15
nozzle
(see Fig. K).
Guide the cable assembly
12
away from
the welding device as straight as possi-
ble (place it on the floor).
Take the wire end out of the edge of the
spool (see Fig L).
Trim the wire end with wire scissors or
a diagonal cutter in order to remove
the damaged, bent ends of the wire
(see Fig. L).
Please note:
The wire must be kept
under tension the entire time in order to
avoid a releasing and a roll out! There-
fore it is recommended to carry out the
work with an additional person.
Push the flux-cored wire through the wire
feed guide
31
(see Fig. M).
Guide the wire along the feed roll
19
and push it into the cable assembly
holder
32
(see Fig. N).
Swivel the thrust roller unit
28
towards
the feed roll
19
(see Fig. O).
Mount the adjustment
27
screw
(see Fig. O).
Set the counter pressure with the adjust-
ment screw. The welding wire must be
firmly positioned between the thrust roller
and feed roll
19
in the upper guide
without being crushed (see Fig. O).
Switch on the welding device on the
main
5
switch.
Press the torch button
11
.
Assembly
Содержание PFDS 120 A2
Страница 3: ...1 2 4 9 10 11 12 3 5 7 6 8 A B C D 13 15 14 16 17 18 22 23 24 25 19 20 21 ...
Страница 24: ...24 GB ...
Страница 47: ...47 HU ...
Страница 48: ...48 HU ...
Страница 68: ...68 SI ...
Страница 88: ...88 CZ ...
Страница 108: ...108 SK ...