Resistor
Range Resolution
Precision
200 Ω
0.1 Ω
± (1.0 % + 5)
2 kΩ
0.001 kΩ
20 kΩ
0.01 kΩ
200 kΩ
0.1 kΩ
2 MΩ
0.001 MΩ
± (1.2 % + 5)
20 MΩ
0.01 MΩ
Overload protection: 300 V
Function generator
Signal Voltage
Output
impedance
1 kHz square wave
signal
approx. 3 V peak-peak
approx. 10 kOhm
The precision quoted in ± (% of d number of digits) applies for 5% to
100% of the relevant measurement range and is guaranteed for a period of one
year at an ambient temperature of 18°C to 28 °C and a max. air humidity of
75%. If the conditions are different, the precision is not guaranteed.
4. Safety instructions
Before you use this multimeter for the first time, please read the following notes
and heed all warnings, even if you are familiar with handling electronic devices.
Keep these operating instructions in a safe place for future reference. If you sell
the multimeter or pass it on, always include these instructions.
WARNING!
This signal word indicates a danger with a
moderate risk, which can lead to death or major injuries if not
avoided.
CAUTION!
This signal word indicates important instructions to
protect against damage to property.