18
GB
IE
than rubber hose lines with the
designation H07RN-F. The pow-
er cable wire cross section must
be at least 2.5 mm
2
Initial Operation
Mount carrying handle
Fix the carrying handle (7) to the
garden pump using the fi xing
screws (8).
Setting up
• Place the unit on a fi rm, horizontal,
non-fl ooding surface.
• If you would like to install the device,
screw it together with the base. A screw
connection with a fastening plate also
prevents the device from slipping.
By doing so, ensure a free access to
the drain screw (
10).
• Always put up the garden pump at a
point higher than the water surface
you wish to pump water from.
Where this is impossible, install a low
pressure-resistant shut-off implement
between the appliance and the suction
hose (available from specialist retailers).
Mains Connection
The pump you have purchases is already
fi tted with an earthed plug. The pump is in-
tended for connection to an earthed socket
at 230 V~ / 50 Hz.
Connecting the hoses
- On the suction side, attach a
hose with backfl ow preventer
and install a prefi lter (available
from specialist retailers).
- If there is a risk of fl ooding,
fi x the plug connections in an
area that is safe from fl ooding.
• Ensure that the mains voltage
matches the specifi cations on the
rating plate.
• The electrical installation shall be
according to national wiring rules.
• Connect the equipment only to
a socket with a residual current
protection device (residual cur-
rent circuit breaker) with a rated
current of not more than 30 mA;
minimum fuse 10 amperes.
• Before each use, check the
equipment, cable and plug for
damage. Defective cables are
not to be repaired, but rather
replaced by new ones. Have
any damage to your equipment
repaired by a specialist.
• If the power cable for this equip-
ment is damaged, it must be
replaced by the manufacturer,
a customer service agent of the
same or a similarly qualifi ed per-
son in order to prevent hazards.
• Do not pull the plug from the sock-
et by the cable. Protect the cable
from heat, oil and sharp edges.
• Do not carry or fi x the equip-
ment by the cable.
• Use only extension cables that
are protected from spray water
and designed for outdoor use.
Always fully unroll a cable drum
before use. Check the cable for
damage.
• Before any work on the equip-
ment, during work breaks and in
the case of non-use, remove the
plug from the socket.
• The cross-section of mains con-
nection lines must be no smaller
Содержание IAN 311554-1904