PHKSA 20-Li A2
■
28
│
GB
│
IE
Attaching/disconnecting the battery
pack to/from the appliance
Inserting the battery pack
♦
Allow the battery pack to click into the
handle.
Removing the battery pack
♦
Press the release button and remove the
battery pack .
Checking the battery charge level
♦
Press the battery charge level button to
check the status of the battery (see fig. A).
The charge status will be shown on the battery
display LED as follows:
RED/ORANGE/GREEN = maximum charge
RED/ORANGE = medium charge
RED = low charge – charge the battery
Checking blade guard functionality
♦
Pull the release lever for the blade guard as
far as it will go.
The blade guard should move without jamming.
When letting go of the release lever for the blade
guard , it should automatically jump back to its
original position.
Operation
Fitting/changing the saw blade
Always remove the battery pack before changing
the saw blade !
1. Set the cutting depth (using the locking
screw ) to the minimum position, 0 mm.
2. Swing the blade guard back using the
release lever and put the appliance down.
3. Press the spindle lock button (until it
engages) and use the hex key to release the
clamping screw . Now remove the clamping
screw and the clamping flange (see also
fig. A).
Fig. A: Changing the saw blade
4. Remove the saw blade .
5. Fitting a saw blade is carried out in the
reverse order.
6. Press the spindle lock button (until it engages)
and use the hex key to tighten the clamping
screw/washer .
WARNING!
►
The arrow on the saw blade must corre-
spond to the arrow showing the direction of
rotation
(running direction shown on the
blade guard ).
■
Ensure that the saw blade is suitable for the
rotational speed of the tool.
IB_356347_PHKSA20-LiA2_LB8.indb 28