GB
│
IE
│
NI
│
25
■
PDRS 6.3 B2
Maintenance and cleaning
WARNING! RISK OF INJURY! Disconnect the tool
from the compressed air supply.
CAUTION!
►
Before maintenance, clean off any hazardous substances that
may have accumulated on the tool (due to working processes) .
Avoid all skin contact with these substances . If the skin comes
into contact with hazardous dusts, this can lead to severe der-
matitis . If dust is produced or swirled up during maintenance, it
can be inhaled .
NOTE
To ensure correct functioning and a long service life for the tool,
pay attention to the following points:
■
Sufficient and continuous oil lubrication is highly important for
optimum functioning .
■
Check the speed and vibration levels after each use .
■
Check the idle speed regularly and after any maintenance is
performed:
use a rev counter and perform the measurement without any
clamped tools . At a residual pressure of 6 .3 bar, the idle speed
may not be exceeded under any circumstances .
■
If the tool is exhibiting excessive vibration levels, the cause of the
vibrations must be identified and repaired .
■
Use only the genuine replacement parts recommended by the
manufacturer, otherwise you could put users at risk . In doubt,
contact the Service Centre .
■
Clean the tool with a soft, dry cloth only .
■
Never use sharp or abrasive cleaning agents under any circum-
stances .