PKZ 180 B2
■
8
│
GB
│
IE
│
NI
using the adapter nozzle
Area of use:
You can insert the adapter nozzle in a vent
valve. You will find this together with other valves
(standard valve, screw valve, ...) on large-volume
items, for example an inflatable mattress.
♦
Press the lever quick coupler downwards to
attach it.
♦
Insert the nozzle adapter into the lever quick
coupler and then release it.
♦
Screw the nozzle adapter into the adapter
nozzle .
♦
Inflate as described above.
Maintenance and cleaning
WARNING! RISK OF INJURY! Switch
the appliance off and remove the
power plug before commencing any
work to the appliance.
■
Do not use any sharp objects to clean the
appliance. Never permit fluids to penetrate
inside the appliance.
The appliance could be
damaged.
■
The appliance is maintenance-free.
■
Ensure that the appliance has cooled down
completely, otherwise there is a risk of burns.
■
The appliance must be depressurised before
all cleaning and maintenance tasks. To do this,
open the release valve until no more air
escapes.
■
Clean the appliance regularly, preferably im-
mediately after completion of the work.
■
Clean the housing with a dry cloth – do NOT
use petrol, solvents or cleaners that can attack
the plastic.
■
Ensure that no water gets into the appliance.
■
Ventilation openings must never be obstructed.
NOTE
►
Replacement parts not listed (such as adapter
nozzles, switch) can be ordered via our
service hotline.
NOTE
This appliance is maintenance free. Never open
the appliance. The appliance may only be re-
paired by an authorised service centre or Cus-
tomer Service. If one of the faults listed below
occurs, note the following:
♦
Disconnect the appliance from any power
supply.
♦
Allow the appliance to cool down and wait a
short while for the residual energy to neutralise.
♦
Ensure that the appliance is in good working
condition.
Troubleshooting
Fault
Solution
1. Appliance
does not
run
1. Check your power supply.
Check that all cables, fuses
and the mains socket are in
working order.
2. Do not use excessively long
extension cables.
3. Do not use the appliance
at temperatures below
+5 degrees.
4. Avoid overheating the
motor. Allow the motor
to cool down.
2. Working
pressure
too low
Check the seals and the non-
return valve. Replace these if
necessary.
3. Tools do
not work
Check the hoses, quick coupler
and the tools. Replace these if
necessary.
Storage
NOTE
►
Store the appliance in a dry and secure envir-
onment. Before storage, the appliance and
all connected compressed air tools should
be bled.
■
Disconnect the mains power plug and then
bleed the appliance and all connected com-
pressed air tools.