background image

Material Clearances 

The stove can be recessed in a suitable sized fireplace but a permanent free air gap of at least 150mm 
must be left around the sides and top and at least 50mm at the back of the stove to obtain maximum heat 
output and for access to the rear of the stove.     
 
All non-combustible walls closer than 300mm to the stove should be at least 75mm thick. 
 
In all instances the hearth should be made of non-combustible material. 
If the back wall of the fireplace is closer than 650mm to the rear of the stove, it should also be made of 
non-combustible material.   
 
Allow an apron of a least 300mm at the front of the stove and 150mm on either side.  
 
The  hearth  on  which  the  stove  is  to  be  placed  should  not  be  less  than  125mm  thick  and  should  be  in 
accordance with the current building regulations.   
 
Care should be taken to level the stove using the adjusting screws in the feet. 
 
The  appliance  shall  be  installed  on  a  floor  with  adequate  load-bearing  capacity.    If  the  existing 
construction  does  not  meet  this  prerequisite,  suitable  measures  (e.g.  load  distributing  plate)  should  be 
taken to achieve it. 
 
 
 

MINIMUM DISTANCE TO COMBUSTIBLE MATERIAL 

Behind the stove 

650mm 

At the side of the stove 

400mm 

 

There should be 

NO

 furniture placed within a distance of 

900mm

 from any surface of the stove. 

 

Note: combustible material refers to any material that will degrade when subjected to heat e.g. plaster. 

 
Material Clearances

 

 

             

 

125mm 

50mm 

150 mm 

300mm 

75mm 

Note: walls and 

hearth shown are 

non-combustible and 
all dimensions stated 

are minimum 

Содержание Consort 7

Страница 1: ... accredited competent person must carry out the installation of this appliance alternatively your local Building Control Officer can approve the completed installation should a non accredited engineer undertake the installation It is an offence under UK law not to comply with this advice Please hand these instructions to the stove user when the installation is complete Leave the system ready for o...

Страница 2: ... at 13 O2 0 27 Mean Flue Gas Temperature 265 C Flue Gas Mass Flow 5 7 g s Ancit Total Efficiency 67 3 Nominal Heat Output 6 5 KW Mean CO Emission at 13 O2 0 22 Mean Flue Gas Temperature 332 C Flue Gas Mass Flow 7 9 g s This appliance is not suitable for use in a shared flue This appliance is suitable for continuous burning ...

Страница 3: ... not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room Flue Collar Place the Flue Gasket on the top or rear outlet as required Place the Flue Collar on top of the Gasket Secure to the four locating tabs inside the flue outlet using the M6 screws supplied Fit the 2 M8 carriage bolts washers nuts into the Damper Holes located on each sid...

Страница 4: ...these Fire Bricks simply reverse the above procedure Remove all the Riddling Bars Cam Bar and Catch Bar from the Stove Slide out and remove both Side Plates Take hold of the Side Brick pull the bottom edge into the Stove Pull the top edge of the Rear Brick towards you lift and remove Lift the Baffle Brick and slide to the right When the left side of the Brick clears the Baffle Support lower the Br...

Страница 5: ...ocal building control department must approve the installation Scheme Web address Telephone APHC Association of Plumbing and Heating Contractors Certification Limited www aphc co uk 02476 470 626 Building Engineering Services Competence Accreditation BESCA Limited www hvca org uk www besca org uk 0800 652 5533 HETAS Ltd Heating Equipment Testing and Approval Scheme www hetas co uk 01462 634721 NAP...

Страница 6: ...under fire at high output If it exceeds the recommended maximum a draught stabiliser must be fitted so that the rate of burning can be controlled and to prevent over firing If the reading is less than the recommended minimum then the performance of the appliance will be compromised Connection to the Chimney An existing fireplace opening can be bricked up or sealed with a register plate A short len...

Страница 7: ... on which the stove is to be placed should not be less than 125mm thick and should be in accordance with the current building regulations Care should be taken to level the stove using the adjusting screws in the feet The appliance shall be installed on a floor with adequate load bearing capacity If the existing construction does not meet this prerequisite suitable measures e g load distributing pl...

Страница 8: ...ast 24 hours On completion of the installation and commissioning ensure that the operating instructions and operating tools for the stove are left with the customer Ensure to advise the customer on the correct use of the appliance with the fuels likely to be used on the stove and warn them to use only the recommended fuels for the stove Advise the user on what to do should smoke or fumes be emitte...

Страница 9: ...e open when the Sliders are pushed towards the outside of the Stove Secondary Air Secondary air is controlled via the slider above the doors it is this Airwash that keeps a clean and uninterrupted view of the fire Tertiary Air Tertiary air aids in good secondary combustion of the fuel and reducing emissions into the chimney and environment Adjusting the cover plate on the back of the stove can con...

Страница 10: ... with the secondary air control in the closed position The primary air sliders can then be used to control the burn rate of the stove For optimum performance when burning only solid mineral fuel it may also be beneficial to close the tertiary air cover plate on the back of the stove Always de ash before refuelling and do not let the ash build up to the underside of the grate bars Solid mineral fue...

Страница 11: ...n close the secondary air slider by moving the handle all the way to the left If the controls are left in this position the fire will receive the minimum of air and will die down If you want to revive the fire it is recommended that the primary air control is open first then open the secondary air slider Warning The stove will remain hot for a considerable time after the fire has been extinguished...

Страница 12: ...t the fire out or eject and safely dispose of fuel from the appliance 3 Check for flue chimney blockage and clean if required 4 Do not attempt to re light the fire until the cause has been identified and corrected If necessary seek professional advice Adverse weather In a small number of installations occasional local weather conditions e g wind from a particular direction may cause downdraught in...

Страница 13: ...ld be avoided as these can scratch the glass and make subsequent cleaning more difficult Wet logs on heated glass a badly aimed poker or heavy slamming of the doors could crack the glass panels The glass will not fracture from heat Firebricks In normal use these can last for many years It is possible however to crack them if logs are continually jammed against them or if they are frequently struck...

Страница 14: ...eck the chimney for potential obstructions before lighting the stove Gaskets All gasket used on this appliance are produced from a heat resistant material called Manniglas The glass gasket will have to be replaced when a new piece of glass is fitted as the gaskets become brittle after firing the stove Over time you may also find that the gasket changes colour This is due to a reduction in the pigm...

Страница 15: ...03 Door Slider CH05 033 Slider Knob HHR08 045 Door Cover CH06 005 Left Hand Door CH06 004 Door Handle CHC04 010 8mm Flat Washer FWFM08 17 M8 Nut FNFN08 x 2 Circlip FLRX07 Shaft CH08 009 Catch HMS04 037 Glass Clip HHR08 046 Glass Clip Screw FSJM05008SS Door Slider CH05 033 Slider Knob HHR08 045 Door Cover CH06 005 Glass Gasket CH06 019 Door Glass CH06 018 Glass Gasket CH06 019 Door Handle CHC04 010...

Страница 16: ...ar Upper CNS04 013 Flue Collar CH08 030 Flue Cover CH08 031 Turbo Bar HH06 101 Rear Brick M F HH06 110 Riddling Support HH06 022 Catch Bar Drop in CNS07 004 Ashpan HH06 025 Side Plates HH06 121 A B Side Brick HH06 115 Rear Brick Wood HH06 116 Log Catch Bar CNS07 006 Top Air Control Slider HH06 086 Slider Plate HH06 087 Gasket HH06 088 Slider Shaft HCE05 021 Slider Knob HHR08 045 ...

Отзывы: