16
Model Number:
SIG 224 G
Appliance Class 2 sub class 1 and Class 1
APPLIANCE CATEGORY
:
II 2H3+
APPLIANCE GAS SUPPLY
: Natural Gas G20 20mbar
Hob
Rear left burner (rapid)
3,000 W
Front left burner (semi-rapid)
2,000 W
Rear right burner (semi-rapid)
2,000 W
Front right burner (auxiliary)
1,000 W
Technical Data
BURNER
RAPID
SEMI-RAPID AUXILIARY OVEN
GRILL
(large)
(medium)
(small)
POSITION
MAX MIN
MAX MIN
MAX
MIN
MAX
MIN
NOMINAL THERMAL
POWER kW
3.0
0.65
2.0
0.45
1.0
0.33
3.0
1.0
2.1
NOMINAL FLOW
RATE m
3
/h
0.286
0.057 0.190
0.038 0.095
0.028
0.286 0.095
0.199
NOZZLE REFERENCE
119
Adjust. 9 6
Adjust.
7 0
Adjust.
116 Adjust.
9 9
NOMINAL THERMAL
POWER kW
2.8
0.65
2.0
0.45
1.0
0.33
3.0
1.0
2.1
NOMINAL FLOW
RATE g/h
202
43.5
144
2 9
7 2
21,5
216
7 2
153
NOZZLE REFERENCE
8 6
4 0
7 1
3 2
5 0
2 8
8 2
5 2
7 1
NATURAL
GAS
20
mbar
TYPE
OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37
mbar
1/100 mm
1/100 mm
VALUE
=
49.92
MJ/Kg
VALUE
=
37.78
MJ/m
3
Ws
- 50.7
MJ/
m
3
Instructions for the Installer
Dimensions
Height
900 mm
Depth
600 mm
Width
497 mm
Oven Capacity
1.7 Cu. ft
Oven
Gas Grill
2,100 W
Oven burner
3,000 W
Oven light
15 W
Supply voltage (50 Hz)
230-240 V
Important Safety Requirements
This appliance must be installed in accordance with the
Gas Safety (Installation and Use) Regulations (current
addition) and the I.E.E. Wiring Regulations. Detailed
recommendations are contained in the following British
Standard Codes of Practice - B.S. 6172, B.S. 5440: Part
2 and B.S. 6891: Current Editions.
Provision for Ventilation
The room containing the cooker should have an air
supply in accordance with B.S. 5440: Part 2: Current
Editions.
The following requirements for ventilation must be met.
The cooker should not be installed in a bed sitting room
with a volume of less than 20m
3
, if it is installed in a room
of volume less 5m
3
an air vent of effective area of 110cm
2
is required; if it is installed in a room of volume between
5m
3
and 10m
3
, an air vent of effective area 50cm
2
is
required, while if the volume exceeds 11m
3
no air vent is
required. However, if the room has a door which opens
directly to the outside, no air vent is required even when
the volume is between 5m
3
and 11m
3
.
If there are other fuel burning appliances in the same
room, B.S. 5440: Part. 2: Current Editions should be
consulted to determine the requisite air vent
requirements.
Содержание SIG 224 G
Страница 23: ......