Maintenance and repair of the adsorber
30
AKM 1-8/D3
Caution!
The spent purifying agent might be contaminated with hazardous substances.
Dispose of it in an environmentally safe manner, taking into account possible
contamination. The waste code number of the purifying agent can be obtained
from the manufacturer.
Dispose of the used purifying agent in
accordance with all applicable regulations.
Replace lower perforated plate
Loosen the screws of the base plate and lift
off the plate.
Remove perforated plate.
Insert new perforated plate.
Removing base plate
Reaffi x the base plate:
Use a dyamometric key to tighten the
screws, and take care to observe the following
torques:
— 25 Nm in the case of AKM 1-4
— 50 Nm in the case of AKM 6-8
Tighten the screws crosswise in accordance
with the sequence shown on the right.
Repeat the process once.
Next the new purifying agent should fi ll up.
Correctly affi xing the base plate
Fill with new drying agent and remount check valve plate
Slowly fi ll up with new purifying agent in the chamber. If necessary, use a funnel. Ensure
that the purifying agent is fi lled into the chamber with a high bulk density.
Subsequently, position the perforated plate onto the top plate, align them properly and
secure them.
Reaffi x the top plate:
Use a dyamometric key to tighten the
screws, and take care to observe the following
torques:
AKM 1-4: approx. 25 Nm
approx. 50 Nm
Tighten the screws crosswise in accordance
with the sequence shown on the right.
Repeat the process once.
Restart the adsorber (see page 18 ).
Check that the connection is leak tight.
Correctly affi xing the top plate