122 VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE
Example
The code following the START label will be run at power up:
1START:
;start label
1T0.5
;delay
1ON
1LIMITS(3,0,0)
;disable limits
1PROFILE1(100,100,4000,25)
;define profile 1
1USE(1)
;use profile 1
1G
;execute profile 1
1END
1ARM1
;arm the start label
1SV
;save the code
Note
If you save the controller with ARM0, then the start-up sequence will fail to
run, and the controller will wait for serial commands.
Using EASI-V software, certain commands become armed when their on/off
parameter is set to ‘on’.
Requesting an ARM status will report the state of the START and FAULT
labels, for example:
aARM
*START 0
*FAULT 1