User Guide
19
Inputs
The following table provides specifications for the multi-purpose inputs when
used as digital inputs:
Digital Input Specifications
Item
MIN
NOM
MAX
UNIT
Input voltage range
0
-
32
V
Overvoltage (5 minutes)
-
-
36
V
Active low pull-up resistance
3.1
3.3
3.5
kΩ
Capacitance at pin
-
0.01
-
µF
Active low - inactive to active threshold
1.23
-
-
V
Active low - active to inactive threshold
-
-
2.60
V
3.3.2.2. Digital Input Configuration
Digital inputs can only be programmed as active low, and they have a pull-up
resistance of 3.3 kΩ.
Since the input is configured as active low, an internal pull-up resistor will be
used, and the input will be active when it is switched to ground.
3.3.2.3. Active-Low Digital Input Connections
An active-low digital input is typically connected to a switch that is either open or
closed.
When the switch is open, the pull-up resistor will ensure no signal exists on
the input pin, which will be interpreted by the VMM1210 as inactive.
When the switch is closed, the input is connected to ground, which will be
interpreted by the VMM1210 as active.
The active-low input must be connected to ground to ensure there is a ground
connection when the state of the input changes.