Parker V Series Скачать руководство пользователя страница 12

8

Collected dust may be hazardous. Consult proper 
authorities for handling and disposal.

!

 

WARNING

6. Service

1. Collected dust may be a potential fire hazard. Refer to Sec-
tion 1 of this manual.
2. Wear appropriate protective clothing.
3. Be environmentally aware of collected dust and its proper 
disposal.
4. Press unit function switch to OFF position. Unplug unit from 
electrical power source.
5. Disconnect compressed air supply to air manifold inlet and 
bleed air supply from manifold.

6.1 Filter Removal and Replacement

As the V Series unit operates and the filter accumulates dust, 
the flow rate of the unit will deteriorate. When the pressure drop 
across the filter continuously reads between 2”-3” or flow drops 
off to the point where the dust generation process cannot ade-
quately be controlled, then it is time to change filters. To change 
filters follow these steps:
1. Remove filter access cover by unscrewing the retaining knob 
(see Figure 8). Tilt cover back away from unit when freed from 
the retaining nut to trap any fugitive dust on the inside of the ac-
cess cover. Dump dust into suitable disposal container.
2. Move filter from side to side to break gasket seal between the 
filter and the tubesheet. Rotate the filter 180° to allow dust on 
top of the cartridge to fall into the dust drawer.
3. Slide filter out along support rods and transfer to suitable dis-
posal container. Empty dust drawer as described in Section 6.2.
4. Inspect tubesheet and make sure the gasket sealing area is 
free of dust to ensure a proper seal.
5. Install a new filter element. Clean access cover gaskets and 
reinstall cover by tightening the knob securely to the retaining 
nut until the gasket is adequately compressed.

6.2 Dust Drawer Removal

1. To access and remove the dust drawer located at the base 
of the V Series unit, you must first unseal the drawer by pulling 
the drawer release handle (see Figure 8) toward the filter access 
side of the cabinet. The drawer will move down and can be 
pulled out of the front of the cabinet.
2. Dispose of the collected dust into a suitable container. Any 
dust in the cabinet that was not contained in the dust drawer 
should be vacuumed out and disposed of.
3. Replace dust drawer by fully inserting into unit, and reseal 
the drawer by pushing the drawer release handle toward the 
control panel.
The collector should now be ready to operate. Reconnect elec-
trical power and air supply. Go through initial start-up checklist 
to ensure proper unit performance.

6.3 After Filter Removal/Installation

If your unit was ordered with a HEPA or carbon after-filter, there 
will be an additional filter housing bolted to the discharge side 
of the V Series unit. The following steps will allow you to re-
move and replace the after-filter as shown in Figure 9. NOTE: 
After-filter housings for portable units (VP) have a push handle 
located on the top of the housing.

1. Release the four draw latches located on the filter housing to 
release the seal of the after-filter.
2. Remove the exhaust screen.
3. The after-filter will slide out of the housing as shown in Figure 9. 
Keep in mind that the filter weight may significantly increase from the 
collected material. Dispose of filter properly.
4. Install a new filter element by sliding it into the filter housing with 
the gasket of the after-filter leading.
5. Replace the exhaust screen and secure the four draw latches to 
seal the filter.

6.4 Servicing Direct Drive Blower

To gain access to the direct drive motor/blower you must first re-
move the discharge air plenum as shown in Figure 7.

NOTE: The blower rotation should be clockwise when looking at the 
motor from the discharge side of the cabinet.

See the troubleshooting guide in Section 8 of this manual for clues 
on motor/blower problems.

Содержание V Series

Страница 1: ...Versatile Portable Cartridge Dust Collector Owner s Manual V Series Models VB VF VP Model VP Model VB Model VF...

Страница 2: ...contacting Parker Parker Order _________________________________________________________________ Unit Model ___________________________________________________________________ Unit Serial ___________...

Страница 3: ...l 3 4 2 2 Downdraft Table Assembly VB Model 3 4 2 3 Fixed Unit Assembly VF Model 4 4 3 Pulse Cleaning 4 4 4 Electrical Installation 4 4 4 1 Pulse Control Timer Board 4 5 Operation 5 5 1 Start Up 5 5 2...

Страница 4: ...tor to put cigarettes or any burning object into the hood or ducting of the swing arm Do not use the Swing Arm to move the portable air cleaner if applicable DA N G E R WARNING C AU T I O N C A U T I...

Страница 5: ...ims any liability or responsibility for damage from fires or explosions regardless of origin Parker recommends that all APC dust collection equipment installation and application conform to any and al...

Страница 6: ...Page intentionally left blank...

Страница 7: ...3 60 All 3 HP Motors are available in 200 230 460 575 3 60 1 1 IMPORTANT NOTICE This manual contains specific information concerning safety and precautionary measures It is impossible to list every po...

Страница 8: ...4...

Страница 9: ...ling duringshipping that may have caused internal damage Notify your de livery carrier and enter a claim if any damage is found Remove the filter access cover located on the front of the unit by turni...

Страница 10: ...ies unit has a wide variety of available electrical options to best meet your needs Take care to ensure proper installation in whatever configuration you have selected For units only requiring a 115 v...

Страница 11: ...Collecting Particles 1 Locate the unit arm and hood in the best position to collect contaminants as generated by the process or operation and where operator interference is minimal 2 Position the hood...

Страница 12: ...at the base of the V Series unit you must first unseal the drawer by pulling the drawer release handle see Figure 8 toward the filter access side of the cabinet The drawer will move down and can be pu...

Страница 13: ...wer 7 2 Cleaning Controls ON OFF Section 4 4 1 of this manual clearly outlines the available settings and operation of the pulse cleaning system Control of the reverse pulse cleaning system is by a ro...

Страница 14: ...g mechanism Filter elements at end of useful life Open solenoid valve Improper electrical supply Refer to Section 7 for electrical specifications Starter overloadtripped Reset overloads Lack of grease...

Страница 15: ...11...

Страница 16: ...12...

Страница 17: ...Series Replacement Parts Item Number Part Number General Description 10 45 10017 0001 Slip Collar 6 DIA V Series Common Replacement Parts Item Number Part Number General Description 11 12 13 14 15 16...

Страница 18: ...IX A V SERIES WRING DIAGRAM Figure 10 Wiring Diagram 120 Volt Single Phase Manual Clean Figure 11 Wiring Diagram 120 Volt Single Phase Pulse Cleaning Figure 12 Wiring Diagram 230 Volt Single Phase Man...

Страница 19: ...e Pulse Cleaning 41 2542 41 2543 Figure 14 Wiring Diagram Three Phase Manual Clean w Parker Supplied Starter Revised 08 09 V SERIES Cartridge Dust Collector Figure 14 Wiring Diagram Three Phase Manual...

Страница 20: ...Cleaning w UAS Supplied Starter Figure 16 Wiring Diagram Three Phase Manual Clean w Customer Supplied Starter 41 2544 Figure 17 Wiring Diagram Three Phase Pulse Cleaning w Customer Supplied Starter 41...

Страница 21: ...17 Page intentionally left blank...

Страница 22: ...or misuse misapplication or normal wear and tear e Equipment not properly installed operated and maintained under normal conditions and recommended applications As Buyers exclusive remedy for any def...

Страница 23: ...shooting effort details 5 Description of physical location and or environment details The Buyer shall cooperate with PARKER in its investigation and provide full information and documentation concerni...

Страница 24: ...rlands 31 76 508 5300 www parker com dhfns Hiross Zander Essen Germany 49 2054 9340 www parker com hzfd Padova Italy 39 049 9712 111 www parker com hzfd Engine Filtration Water Purification Racor Dews...

Отзывы: