Parker Racor Turbine Series Скачать руководство пользователя страница 12

12

February 2013

© Parker Hannifin Corporation

All products manufactured 
or distributed by Racor are 
subject to the following, and 
only the following, LIMITED 
EXPRESS WARRANTIES, and 
no others: For a period of 
one (1) year from and after 
the date of purchase of a new 
Racor product, Racor warrants 
and guarantees only to the 
original purchaser-user that 
such a product shall be free 
from defects of materials 
and workmanship in the 
manufacturing process. The 
warranty period for pumps and 
motors is specifically limited 
to ninety (90) days from date of 
purchase. A product claimed to 
be defective must be returned 
to the place of purchase. Racor, 
at its sole option, shall replace 
the defective product with a 
comparable new product or 
repair the defective product. 
This express warranty shall be 
inapplicable to any product not 
properly installed and properly 
used by the purchaser-user 
or to any product damaged or 
impaired by external forces. 

THIS IS THE EXTENT OF 
WARRANTIES AVAILABLE 
ON THIS PRODUCT. RACOR 
SHALL HAVE NO LIABILITY 
WHATSOEVER FOR 
CONSEQUENTIAL DAMAGES 

FLOWING FROM THE USE OF 
ANY DEFECTIVE PRODUCT 
OR BY REASON OF THE 
FAILURE OF ANY PRODUCT. 
RACOR SPECIFICALLY 
DISAVOWS ALL OTHER 
WARRANTIES, EXPRESS 
OR IMPLIED INCLUDING, 
WITHOUT LIMITATION, ALL 
WARRANTIES OF FITNESS 
FOR A PARTICULAR PURPOSE 
(EXCEPT FOR THOSE WHICH 
APPLY TO PRODUCT OR 
PART THEREOF THAT IS 
USED OR BOUGHT FOR USE 
PRIMARILY FOR PERSONAL, 
FAMILY, OR HOUSEHOLD 
PURPOSES), WARRANTIES OF 
DESCRIPTION, WARRANTIES 
OF MERCHANTABILITY, 
TRADE USAGE OR 
WARRANTIES OR TRADE 
USAGE.

Warning

Failure or improper selection 
or improper use of the 
products and/or systems 
described herein or related 
items can cause death, 
personal injury and property 
damage. This document and 
other information from Parker 
Hannifin Corporation, its 
subsidiaries and authorized 
distributors provide product 

and/or system options for 
further investigation by users 
having technical expertise. 
It is important that you 
analyze all aspects of your 
application and review the 
information concerning the 
product or system in the 
current product catalog. Due 
to the variety of operating 
conditions and applications 
for these products or systems, 
the user, through its own 
analysis and testing, is solely 
responsible for making the 
final selection of the products 
and systems and assuring that 
all performance, safety and 
warning requirements of the 
applications are met.   
The products described 
herein, including with 
limitation, product features, 
specifications, designs, 
availability and pricing, are 
subject to change by Parker 
Hannifin Corporation and 
its subsidiaries at any time 
without notice.

The following statement 
is required pursuant to 
proposition 65, applicable 
in the State of California: 
‘This product may contain a 
chemical known to the State of 
California to cause cancer or 
reproductive toxicity’.

Limited Warranties Statement

Содержание Racor Turbine Series

Страница 1: ...r When heavy enough they too fall to the bottom of the collection bowl Stage 3 Filtration Proprietary Aquabloc cartridge filters repel water and remove contaminants from fuel down to 2 micron nominal Aquabloc cartridge filters are waterproof and effective longer than water absorbing filters Instruction Part Number 12960 Rev E Contact Information Parker Hannifin Corporation Racor Division P O Box 3...

Страница 2: ...uum Side Installation Fuel Tank Vacuum Side Installation Install a check valve with light or no restriction when tank is lower than filter to maintain prime Pressure Side Fuel transfer pump not to exceed maximum PSI or flow rate of filter NOT ideal pumps emulsify water hindering filter performance Fuel transfer pump IDEAL vacuum side installation Engine Maintain a service clearance below filter as...

Страница 3: ...bends with flexible fuel hose as kinks may occur Avoid the use of two 45 elbow fittings where one 90 elbow will work When routing hose avoid surfaces that move have sharp edges or get hot such as exhaust piping Priming Instructions 1 Remove T handle and lid from top of filter 2 Fill filter with clean fuel 3 Lubricate lid gasket and T handle O ring with clean fuel or motor oil 4 Replace lid and T h...

Страница 4: ...is operated by turning the ignition switch ON for a minimum of five minutes prior to starting the engine HEATER WIRING INSTALLATION Caution Please read carefully before beginning installation See schematic on next page 1 Never power up the heater if there is no fuel in the Racor filter severe damage may result to the heater and filter assembly 2 During equipment or vehicle servicing always ensure ...

Страница 5: ...RK 11862 Dual 2 RK 19490 24 Racor Heater Relay Kit Information Note Racor heater relay kits are ordered separately Battery Ignition Switch black 14 Green 14 red 14 white 18 Optional Toggle Switch Red 18 Black 14 Fuse Box 1A Min Inlet Port Racor Relay Kit Racor 3 wire Schematic Shown Note If your Racor heater has only 2 wires no white the relay White 18 wire simply goes to chassis ground White 18 ...

Страница 6: ...cm Weight dry 6 0 lb 2 7 kg Clean Pressure Drop 0 30 PSI 0 021 bar Maximum Pressure1 15 PSI 1 03 bar Water In Bowl Capacity 10 3 oz 305 ml Available Options water detection kit 2 12 or 24 vdc heater 2 vacuum gauge 12 or 24 vdc primer pump Yes Yes Yes Yes Water Removal Efficiency 99 Ambient Temperature Range 40 o to 255 o F 40 o to 124 o C Maximum Fuel Temperature 190 F 88 C 1 Pressure installation...

Страница 7: ... Body Feed thru Kit includes A B 6 5 RK 11815 103 Mounting Bracket Kit 6 RK 19663 RK 11 1679 3 wire Feed thru Heater Assembly Kit Body Feed thru Plug Kit 7 RK 11 2009 Kit Body Housing Return Tube includes B 3 pcs G 8 RK 11 1939 Conical Baffle and Turbine Centrifuge Kit includes B C D E 9 RK 11 1938 See thru Bowl with Drain and Plug Kit includes B F 10 10 RK 32204 Water Sensor Kit 11 RK 20126 Bowl ...

Страница 8: ...h 7 0 in 17 8 cm Width 6 0 in 15 2 cm Weight dry 10 0 lb 4 5 kg Clean Pressure Drop 0 43 PSI 0 03 bar Maximum Pressure1 15 PSI 1 03 bar Water In Bowl Capacity 10 3 oz 305 ml Available Options water detection kit 2 12 or 24 volt dc heater 2 vacuum gauge 12 or 24 vdc primer pump Yes Yes Yes Yes Water Removal Efficiency 99 Ambient Temperature Range 40o to 255o F 40o to 124o C Maximum Fuel Temperature...

Страница 9: ...2015 24 vdc Heater Body Feed thru Kit includes A B 6 5 RK 11815 103 Mounting Bracket Kit 6 RK 19663 RK 11 1679 3 wire Feed thru Heater Assembly Kit Body Feed thru Plug Kit 7 RK11 2010 Kit Body Housing Return Tube includes B 3 pcs G 8 RK 11 1939 Conical Baffle and Turbine Centrifuge Kit includes B C D E 9 RK 11 1938 See thru Bowl with Drain and Plug Kit includes B F 10 10 RK 32204 Water Sensor Kit ...

Страница 10: ...h this surface Check O ring for damage Damaged worn or dirty seals will allow air ingestion Inspect and replace all seals as needed Clean the sealing surfaces of dirt or debris every time the filter is replaced If carriage bolt is loose do not overtighten it as this may distort the bracket position Heater feed thru O ring must not be damaged or swollen Tighten to 15 20 in lbs Air bubbles appearing...

Страница 11: ...e outlet hole on fuel return tube if filter is removed and fuel will not flow to engine Instead punch emergency tab on the top of filter and leave in place Puncturing emergency tab will bypass all filtration and send unfiltered fuel to your engine Service filter as soon as possible to avoid harmful contaminants flowing downstream to the final filter or engine Water Sensors This feature alerts oper...

Страница 12: ... TO PRODUCT OR PART THEREOF THAT IS USED OR BOUGHT FOR USE PRIMARILY FOR PERSONAL FAMILY OR HOUSEHOLD PURPOSES WARRANTIES OF DESCRIPTION WARRANTIES OF MERCHANTABILITY TRADE USAGE OR WARRANTIES OR TRADE USAGE Warning Failure or improper selection or improper use of the products and or systems described herein or related items can cause death personal injury and property damage This document and oth...