Owner’s Manual With Instructions
Parker Racor Absolute Oil Cleaner Demo Machine
Page | 4
Instruction #New 07202011
4. Remove the tank fill plug with a 5/8” / .625 allen hex wrench.
5. Fill the storage tank to just below the plug opening. This will require approximately 6 quarts /
5.7 liter of fluid.
6. Replace the tank fill port plug and tighten until the o-ring is seated.
7. Locate the brass valve forward of the fill plug and rotate 90
⁰
clockwise until it stops.
8. Locate the drain valve on the left side of the Demo Machine and make sure it is closed. The
valve handle will be turn at a right angle.