Parker R4V Series Скачать руководство пользователя страница 14

Pilot Operated Pressure Relief Valves

Series R4V*/R6V*/DSDU* 

14

Parker Hannifin Corporation

Parker Hannifin Corporation

Translation from German

R_V-DSDU 5715-661 UK.indd 11.12.19

EC Declaration of Conformity / Translation from German

2006/42/EC

Mr Günther Funk is authorised to compile the technical file.
For enquiries, see the company address.

Parker Hannifin Manufacturing Germany GmbH & Co. KG declares that the safety valves

Type R4V*V and R4V*W
Type R6V*V and R6V*W
Type DSDU 578 P20E TÜV and DSDU 1078 E*E TÜV

fulfil all the relevant provisions of the

Machinery Directive 2006/42/EC

and

also fulfil all the relevant provisions of the following EC Directives:

Pressure Equipment Directive 97/23/EC

The valves have been approved for module G / category IV / fluid group 1 as defined in the Pressure Equipment 
Directive 97/23/EC, by
TÜV Industrie Service GmbH
Gottlieb-Daimler-Str. 7 
70794 Filderstadt
ID 0036

Harmonised standards applied:
DIN EN ISO 4126-4:2004-05  

 

Safety devices for protection against excessive pressure

DIN EN 60529:2000-09  

 

Degrees of protection provided by enclosures (IP code)

National standards and technical specifications applied:
VDTÜV Merkblatt Sicherheitsventil 100 (Safety Valves)
AD-2000-Regelwerk W3/2 - Spheroidal-graphite cast iron, non-alloy and low alloy

Place, Date: 

Kaarst, 11.07.2011

Signature:
The undersigned: 

Hansgeorg Kolvenbach / Business Unit Manager Industrial Valves

Parker Hannifin 

Manufacturing Germany GmbH & Co. KG

Hydraulic Controls Division Europe

Gutenbergstrasse 38

41564 Kaarst, Deutschland

  Any unauthorised structural change or 

addition to the product may jeopardise 
safety to an unacceptable degree. This 

would invalidate the declaration of con-
formity supplied with the product.

Declaration of Conformity

Содержание R4V Series

Страница 1: ...ctions Series R4V and R6V Pilot operated pressure relief valve Subplate mounted Series DSDU Pilot operated pressure relief valve 2 way cartridge valves Parker Hannifin Manufacturing Germany GmbH Co KG...

Страница 2: ...election of the system and components and assuring that all performance endurance maintenance safety and warning requirements of the application are met The user must analyze all aspects of the applic...

Страница 3: ...ightning 7 Temperature 7 Power failure 7 Pressure relief valve series R4V V R4V W R6V V R6V W with vent function 7 4 Correct use 8 5 Function 8 Series DSDU 8 Series R4V V R4V W R6V V R6V W without ven...

Страница 4: ...ct If the product is used with safety devices that are defective or not properly installed Iftheoperatinginstructionsarenotfollowedwith regard to transport storage commissioning operation modification...

Страница 5: ...selected from the catalogue Electronics section Please ask the factory if you are not clear Connecting to an unsuitable electronic control system may result in irreparable damage to the valve or the e...

Страница 6: ...This product is a safety component that mayonlyberepairedbythemanufacturer if it malfunctions If the safety components are repaired by the user the manufacturer s warranty is invalidated because the...

Страница 7: ...nt details can be found in Technical data section 16 The ambient conditions must be ob served Unauthorised temperatures shocks the effects of aggressive chemi cals radiation unauthorisedelectromag net...

Страница 8: ...al packaging until it is ready to use Note also the information in sections 1 Warranty and liability 2 Use of operating instructions Compliance with other rules and instructions Personnel requirements...

Страница 9: ...sioning the specialist personnel must verify that the entire hydraulic system has been installed correctly Commissioningmustbecarriedoutwith care taking account of all safety regula tions 7 Storage If...

Страница 10: ...nstructions Personnel requirements and 3 Remaining risk Installation instructions DSDU The valve as packed consists of several individual parts which are packed separately When remov ing the product f...

Страница 11: ...possible Otherwise return the valve to the manu facturer Leakage at the valve O ring at the mating flange leaking or missing Shut down the system machine immediately Replace the O ring Plug plunger tu...

Страница 12: ...d instructions Personnel requirements and 3 Remaining risk 11 Modification We define modification as the replacement of a defective valve with a new valve of the same series Make sure that the hydraul...

Страница 13: ...sive pressure Part 4 Pilot operated safety valves DIN EN 60204 1 2007 06 VDE 0113 1 2007 06 Safety of machinery Electrical equipment of machines Part 1 General requirements DIN EN 60529 2014 09 VDE 0...

Страница 14: ...e Pressure Equipment Directive 97 23 EC by T V Industrie Service GmbH Gottlieb Daimler Str 7 70794 Filderstadt ID 0036 Harmonised standards applied DIN EN ISO 4126 4 2004 05 Safety devices for protect...

Страница 15: ...operating pressure bar Ports A and X 350 B and Y depressurised Pilot oil external external Pressure setting bar See ordering information Nominal flow l min See ordering information Fluid Hydraulic oil...

Страница 16: ...16 6 70 41 35 NG m4 0 2 t1 0 1 t2 0 1 t3 t4 t4 max t5 t6 t7 t8 t10 U W 16 10 5 43 56 11 34 29 5 20 20 2 2 10 0 03 0 05 25 16 58 72 12 44 40 5 30 25 2 5 2 5 10 0 03 0 05 32 17 70 85 13 52 48 0 30 35 2...

Страница 17: ...16 13 R V with vent function General Nominal size 25 32 Interface Subplate mounting acc ISO 6264 Mounting position as desired horizontal mounting prefered Ambient temperature C 20 60 MTTFD value year...

Страница 18: ...21 5 7 2 21 5 66 7 58 8 33 4 7 9 14 3 25 6264 08 11 97 60 3 49 2 39 7 11 1 20 6 79 4 73 39 7 6 4 15 9 32 6264 10 15 97 84 2 67 5 59 5 42 1 16 7 24 6 96 8 92 8 48 4 3 8 21 4 R4V without vent function...

Страница 19: ...0 30 Y external drain port G 1 8 NG ISO Code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6 25 6264 08 13 97 66 7 55 6 23 8 11 1 33 4 70 35 32 6264 10 17 97 88 9 76 2 31 8 12 7 44 5 82 6 41 3 Tolerance at X a...

Страница 20: ...6264 10 17 97 88 9 76 2 31 8 12 7 44 5 82 6 41 3 Tolerance at X and Y pin holes and screw holes 0 1 at port holes 0 2 NG ISO Code d1max d2max d3 t3 d4 t4 d5 d6 25 6264 08 13 97 23 4 6 3 7 5 10 M16 27...

Отзывы: