Parker R4V Series Скачать руководство пользователя страница 1

Bulletin MSG11-5715-661/UK

Operating instructions
Series R4V*V* / R4V*W*
Series R6V*V* / R6V*W*
Series DSDU*1078 E*E TÜV

Translation of German original operating instructions

Series R4V and R6V

Pilot operated pressure relief valve
Subplate mounted

Series DSDU

Pilot operated pressure relief valve
2-way cartridge valves

Parker Hannifin 
Manufacturing Germany GmbH & Co. KG

Industrial Systems Division Europe
Gutenbergstr. 38
41564 Kaarst, Germany
Tel.: (+49) 181 99 44 43 0
E-mail: [email protected]
Copyright © 2019, Parker Hannifin Corp.

Содержание R4V Series

Страница 1: ...ctions Series R4V and R6V Pilot operated pressure relief valve Subplate mounted Series DSDU Pilot operated pressure relief valve 2 way cartridge valves Parker Hannifin Manufacturing Germany GmbH Co KG...

Страница 2: ...election of the system and components and assuring that all performance endurance maintenance safety and warning requirements of the application are met The user must analyze all aspects of the applic...

Страница 3: ...ightning 7 Temperature 7 Power failure 7 Pressure relief valve series R4V V R4V W R6V V R6V W with vent function 7 4 Correct use 8 5 Function 8 Series DSDU 8 Series R4V V R4V W R6V V R6V W without ven...

Страница 4: ...ct If the product is used with safety devices that are defective or not properly installed Iftheoperatinginstructionsarenotfollowedwith regard to transport storage commissioning operation modification...

Страница 5: ...selected from the catalogue Electronics section Please ask the factory if you are not clear Connecting to an unsuitable electronic control system may result in irreparable damage to the valve or the e...

Страница 6: ...This product is a safety component that mayonlyberepairedbythemanufacturer if it malfunctions If the safety components are repaired by the user the manufacturer s warranty is invalidated because the...

Страница 7: ...nt details can be found in Technical data section 16 The ambient conditions must be ob served Unauthorised temperatures shocks the effects of aggressive chemi cals radiation unauthorisedelectromag net...

Страница 8: ...al packaging until it is ready to use Note also the information in sections 1 Warranty and liability 2 Use of operating instructions Compliance with other rules and instructions Personnel requirements...

Страница 9: ...sioning the specialist personnel must verify that the entire hydraulic system has been installed correctly Commissioningmustbecarriedoutwith care taking account of all safety regula tions 7 Storage If...

Страница 10: ...nstructions Personnel requirements and 3 Remaining risk Installation instructions DSDU The valve as packed consists of several individual parts which are packed separately When remov ing the product f...

Страница 11: ...possible Otherwise return the valve to the manu facturer Leakage at the valve O ring at the mating flange leaking or missing Shut down the system machine immediately Replace the O ring Plug plunger tu...

Страница 12: ...d instructions Personnel requirements and 3 Remaining risk 11 Modification We define modification as the replacement of a defective valve with a new valve of the same series Make sure that the hydraul...

Страница 13: ...sive pressure Part 4 Pilot operated safety valves DIN EN 60204 1 2007 06 VDE 0113 1 2007 06 Safety of machinery Electrical equipment of machines Part 1 General requirements DIN EN 60529 2014 09 VDE 0...

Страница 14: ...e Pressure Equipment Directive 97 23 EC by T V Industrie Service GmbH Gottlieb Daimler Str 7 70794 Filderstadt ID 0036 Harmonised standards applied DIN EN ISO 4126 4 2004 05 Safety devices for protect...

Страница 15: ...operating pressure bar Ports A and X 350 B and Y depressurised Pilot oil external external Pressure setting bar See ordering information Nominal flow l min See ordering information Fluid Hydraulic oil...

Страница 16: ...16 6 70 41 35 NG m4 0 2 t1 0 1 t2 0 1 t3 t4 t4 max t5 t6 t7 t8 t10 U W 16 10 5 43 56 11 34 29 5 20 20 2 2 10 0 03 0 05 25 16 58 72 12 44 40 5 30 25 2 5 2 5 10 0 03 0 05 32 17 70 85 13 52 48 0 30 35 2...

Страница 17: ...16 13 R V with vent function General Nominal size 25 32 Interface Subplate mounting acc ISO 6264 Mounting position as desired horizontal mounting prefered Ambient temperature C 20 60 MTTFD value year...

Страница 18: ...21 5 7 2 21 5 66 7 58 8 33 4 7 9 14 3 25 6264 08 11 97 60 3 49 2 39 7 11 1 20 6 79 4 73 39 7 6 4 15 9 32 6264 10 15 97 84 2 67 5 59 5 42 1 16 7 24 6 96 8 92 8 48 4 3 8 21 4 R4V without vent function...

Страница 19: ...0 30 Y external drain port G 1 8 NG ISO Code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6 25 6264 08 13 97 66 7 55 6 23 8 11 1 33 4 70 35 32 6264 10 17 97 88 9 76 2 31 8 12 7 44 5 82 6 41 3 Tolerance at X a...

Страница 20: ...6264 10 17 97 88 9 76 2 31 8 12 7 44 5 82 6 41 3 Tolerance at X and Y pin holes and screw holes 0 1 at port holes 0 2 NG ISO Code d1max d2max d3 t3 d4 t4 d5 d6 25 6264 08 13 97 23 4 6 3 7 5 10 M16 27...

Отзывы: