background image

MSG33-5026-IB/US 

06/12/2019

© 2019 Parker Hannifin Corporation. All rights reserved.

Your Local Authorized Parker Distributor

Parker Hannifin Canada

Electronic Controls Division

1305 Clarence Avenue
Winnipeg, MB, R3T 1T4 Canada
phone 204 452 6776
fax 204 478 1749
www.parker.com/ecd

Содержание PVSG

Страница 1: ...PVSG User Guide Parker Vehicle System Gateway Effective June 2019 Supersedes UG PVSG 1051000 201906 003...

Страница 2: ...product and or system options for further investigation by users having technical expertise The user through its own analysis and testing is solely responsible for making the final selection of the s...

Страница 3: ...pabilities 6 3 1 1 Power control digital input connections 7 3 1 2 Active high digital input connections 7 4 Outputs 9 4 1 Output capabilities 9 4 2 High side output connection 9 5 Power 11 6 Communic...

Страница 4: ...PVSG User Guide IV...

Страница 5: ...the changes made to this document over the course of its publication history Release Date Description of Change Rev 001 First release of this document Rev 002 Realignment to match platform changes Min...

Страница 6: ...hydraulics control electronics may only be carried out by trained personnel who are well acquainted with the control system the machine and its safety regulations Follow the manufacturer s regulations...

Страница 7: ...stop must be easily accessible to the operator If possible the machine must be built so that the supply voltage to the control system s electrical units is disconnected when the operator leaves the op...

Страница 8: ...nding on version 1x high side output depending on version Figure 1 1 PVSG module The design of the gateway platform is structured to provide two levels of connectivity Packages of software capability...

Страница 9: ...gging memory 0 Memory for logging events CAN messages etc RTC 1 Real time clock Inputs 2 Active high GPIO with wake up capability Outputs 1 High side Advanced Characteristic Number Description CAN bus...

Страница 10: ...ey option B 334722007 334722002 J2 connector black 20 pin key option A 334721606 334721601 Contacts 330013004 16 20 awg gold 330013004 16 20 awg gold The pins in the Molex MX150 connectors are used fo...

Страница 11: ...Function 1 GND J1708A 2 CAN_L J1708B 3 GND GND Negative battery 4 LIN2 LIN2 5 GND GND Negative battery 6 LIN1 LIN1 7 NC Reserved 8 OUTPUT1 Output1 9 NC Reserved 10 GND GND Negative battery 11 LIN4 LIN...

Страница 12: ...AMP 4 2271112 1 The following tables shows the pin outs for the M12 connectors J11 Connector Pinout Pin I O Name Function 1 Ethernet_TX Ethernet Transmit 2 Ethernet_RX Ethernet Receive 3 Ethernet_TX...

Страница 13: ...s INPUT1 and INPUT2 This GPIO Type 1 input provides a fixed input detection threshold with fixed pull down resistance The primary function of the inputs is to provide a wake on ignition feature as a d...

Страница 14: ...er Control Input Power Control Pull Down Resistor Battery Application Switch Figure 3 1 Power control digital input installation connections 3 1 2 Active high digital input connections A digital input...

Страница 15: ...e 8 The following diagram shows a typical active high digital input connection Internal to product Active High Digital Input Battery Application Switch Figure 3 2 Active high digital input installatio...

Страница 16: ...d type in a vehicle High side output can source up to 0 25 A max High side output have internal flyback diodes which are needed when driving inductive loads the flyback diodes absorb electrical energy...

Страница 17: ...PVSG User Guide 10 The following shows a typical high side output connection Internal to product High Side Output Application Load Figure 4 1 High side output installation connections...

Страница 18: ...n configuration The PVSG in a 12 V or 24 V system and can operate from 6 5 V up to 32 V with over voltage protection at 36 V The following table provides specifications for the PVSG power Item Min Nom...

Страница 19: ...using Wake on CAN For this reason any message will turn on the PVSG The application software must be written to determine how the PVSG will behave when it is turned on The following table provides spe...

Страница 20: ...AN connectors are manufactured by ITT Cannon and Deutsch and come in either T or Y configurations CAN Harness The CAN harness is the main backbone cable that is used to connect the CAN network This ca...

Страница 21: ...erference Causing Equipment Regulations Wireless operation is subject to 2 conditions The first is that the wireless device may not cause interference The second is that the wireless device must accep...

Страница 22: ...o between a computer and the vehicle The PVSG can has 1 of this type communication port The J1708 port is provided to connect J1939 networks to legacy J1708 protocol devices Note On power up the PVSG...

Страница 23: ...PVSG User Guide 16...

Страница 24: ...ally attaching the PVSG to a vehicle Secure the PVSG with bolts in all bolt holes using Hex Head 1 4 20 or equivalent metric size M6 bolts The bolts should be tightened according to the recommended in...

Страница 25: ...PVSG User Guide 18 7 3 Dimensions The following shows the dimensions of the PVSG in millimeters Figure 7 1 PVSG dimensions...

Страница 26: ...r Hannifin Corporation All rights reserved Your Local Authorized Parker Distributor Parker Hannifin Canada Electronic Controls Division 1305 Clarence Avenue Winnipeg MB R3T 1T4 Canada phone 204 452 67...