Parker PTR Series Скачать руководство пользователя страница 4

4

STROKE ADJUST OPTIONS

30° STROKE ADJUST OPTION WITH  BUMPER

30° STROKE ADJUST OPTION

ITEM

NO.

DESCRIPTION

QTY.

36

PISTON BOLT

1

37

END CAP

1

38

THREAD SEAL

1

39

LOCK WASHER

1

40

JAM NUT

1

41

STROKE ADJUSTER

1

42

STROKE ADJUST HEAD

1

43

STROKE ADJUST BLOCK

1

44

O-RING, STROKE ADJUST BLOCK

1

45

END CAP

1

19

37

38

18

42

39

41

40

41

40

38

43

46

49

25

27

22

23

20

39

21

24

10° STROKE ADJUSTMENT

 WITH CUSHION OPTION

(Single Rack Units Only)

36

39

37

38

41

40

NOTE:

Quantities shown are as required per end cap option
specified.

Stroke adjusters will reduce the angle of rotation by 10° or
30° in either or both directions.  Typical applications are for
initial set up purposes where exact rotation requirements
may change between various operations.

CAUTION:   Before making any adjustments, turn off system

pressure and ensure that no residual pressure
exists in the actuator.

Standard cushions operate over the last 30° of rotation.
Stroke adjusters will decrease the cushion length by the
same amount.  For example, reducing the rotation by 5°
yields 25° cushion length.

To Adjust:
1. Loosen Jam Nut, #40.
2. Turn Stroke Adjuster, #41 clockwise to reduce stroke,

counterclockwise to increase stroke.

3. Tighten Jam Nut, #40.
4. Resume system pressure.

PTR/LTR

MODEL

ONE COMPLETE TURN OF

ADJUSTER CAUSES SPECIFIED

CHANGE IN ROTATION

101/102

4.0°

151/152

4.6°

201/202

3.2°

251/252

3.2°

312/322

2.4°

Содержание PTR Series

Страница 1: ...15 and O Ring End Cap 12 1 Remove Tie Rod Nuts 17 from Tie Rods 8 2 Pull End Cap 16 free from Cylinder Tube 14 3 Pull CylinderTube 14 free from Housing 13 4 Push Piston 11 free from Cylinder Tube 14 5...

Страница 2: ...11 PISTON 2 4 12 O RING END CAP 2 4 13 HOUSING 1 1 14 CYLINDER TUBE 2 4 15 WEAR RING 4 8 16 END CAP 2 4 17 TIE ROD NUT 8 16 18 BUMPER 1x 1x 19 BUMPER BOLT 1x 1x All items marked with an asterick are i...

Страница 3: ...LUG 1 26 END CAP 1 27 CUSHION BUSHING 1 28 O RING ADJUSTMENT SCREW 1 29 FLOW CONTROL ADJ SCREW 1 30 END CAP 1 31 PLUG 1 32 O RING PLUG 1 33 CHECK BALL 1 34 CHECK SPRING 1 35 CHECK PLUG 1 PORT FLOW CON...

Страница 4: ...30 in either or both directions Typical applications are for initial set up purposes where exact rotation requirements may change between various operations CAUTION Before making any adjustments turn...

Страница 5: ...ve Load PC Sequencer 10 100 mA Inductive Load Relay Switching Response 300 Hz Maximum Breakdown Voltage 1 8kVACrms for 1 sec lead to case Min Current for LED 18mA Operating Temperature 14 to 140 F 10...

Страница 6: ...power removed to reset the switch preventing automatic restarts The low voltage DC switch is also available for use with 10 30 VDC This switch is in a non rotatable housing but does incorporate the sh...

Страница 7: ...adjustment screws will be marked C and P respectively Cushion Adjust ment Screw 74 can be turned clockwise for more cushion counter clockwise for less cushion Always set flow control adjustment screw...

Страница 8: ...es specifications designs availabilityand pricing are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice STOP TUBE C 3 C 4 C 2 C 1 S14 P5 P3 P1 P2 S12 P4...

Отзывы: