Parker PowerStation RS9 Скачать руководство пользователя страница 1

CTC Parker Automation

A3-06134-100

R S 9   C D - R O M   R e p l a c e m e n t

Introduction

These instructions explain how to replace a CD-ROM drive in the Power-
Station RS9 or the RSPC9 Industrial PC. They include steps for disassem-
bling the unit, removing a previously installed drive, installing a new drive, 
and reassembling the unit.

Warning

For safety reasons, the unit should be opened only by qualified 
service personnel.

Warning

Be sure to observe electrostatic discharge (ESD) precautions 
while working inside the unit.

To complete this procedure, you will need the following items:

CD-ROM Replacement Kit CDR-9000

Phillips-head screwdriver

Disassembling the Unit

To disassemble the unit, follow these steps:

1. Turn off the system.

2. Disconnect the unit from the power source.

3. Disconnect all cables attached to the unit.

4. Remove the unit from its mounted location by lifting the unit up 

and off its mounting screws. 

5. Place the unit on a static dissipative mat, in a location free from 

dirt and moisture and protected against static discharge. 

6. Remove the two screws at the left side of the front cover, as shown 

in Figure 1 on page 2. 

Note

These screws unscrew from the back side of the unit.