WARNING!

Don not combine drain lines.

Maximum continuous case pressure:

p

case

= 0,5 bar 

Maximum intermittent peak case pressure:

p

case

= 2 bar 

WARNING!

Don not restrict drain line.

A restricted drain line can damage the pump.

www.comoso.com

Содержание P2 Series

Страница 1: ...PUMP AND MOTOR DIVISION Neefestraße 96 09116 Chemnitz Germany INSTALLATION MANUAL SERIES P2 and P3 MOBILE PISTON PUMP www comoso com ...

Страница 2: ...with your paper work Nameplate of the pump Ordering Sales Acknowledgement 2 Check rotation of the pump Clockwise rotation right side ported P2 Clockwise rotation right thru drive P3 Counter clockwise rotation right side ported P2 Counter clockwise rotation right thru drive P3 www comoso com ...

Страница 3: ...ump inlet pressure under static and dynamic load pin min 0 8 bar absolute Maximum pump inlet pressure pin max 10 bar Arrangement outside tank Fill pump case with oil before start Do not restrict suction line Arrangement outside tank Fill pump case with oil before start Do not restrict suction line 3 1 1 Arrangements P2 www comoso com ...

Страница 4: ...de tank Fill pump case with oil before start Do not restrict suction line Preferred arrangement for best suction characteristics low noise level operation 3 1 2 Drain line connection P2 OPTION Connect highest drain port with a separate line reduced in size for purging the air out of the case AND secondary drain port has to be connected as main drain line www comoso com ...

Страница 5: ...Chemnitz Germany WARNING Don not combine drain lines Maximum continuous case pressure pcase 0 5 bar Maximum intermittent peak case pressure pcase 2 bar WARNING Don not restrict drain line A restricted drain line can damage the pump www comoso com ...

Страница 6: ...start up Do not restrict suction line Arrangement outside tank Fill pump case with 0 5 l of fluid prior to start up Do not restrict suction line 3 2 1 Arrangements P3 Arrangement outside tank Fill pump case with 0 5 l of fluid prior to start up Do not restrict suction line Arrangement outside tank Fill pump case with 0 5 l of fluid prior to start up Do not restrict suction line Preferred arrangeme...

Страница 7: ...CTION Connect compensator drain line with the reservoir Keep inlet and drain line separate hot loop ATTENTION Combination and restriction of compensator drain line may result an back pressure Maximum continuous drain line pressure pdrain 2 bar Maximum intermittent peak drain line pressure pdrain 4 bar www comoso com ...

Страница 8: ...in line as well as drive speed Drain Port on both sides available Beneath the design itself pumps with inlet drain port configuration can be identified by the last 25th digit of the order code If this one is D or E drain line has to be connected to the drain port in rearcover In case of U or P the pump still features a compensator with drain port see installation manual pages 3 and 4 Shipping plug...

Страница 9: ...using water based fluids 5 2 Cleanliness level Recommendation for maximized component life and reliability Class 21 18 14 according to ISO 4406 5 3 Viscosity range Minimum viscosity for short periods 10 mm s cSt Normal operating viscosity 15 40 mm s cSt Maximum viscosity for short periods 1000 mm s cSt 6 Temperature 6 1 Check hydraulic fluid specification for chemical resistance of seal material 6...

Отзывы: