![Parker P1V-A160B Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/parker/p1v-a160b-series/p1v-a160b-series_manual_3961705008.webp)
8
www.parker.com/euro_pneumatic
Service kits
The following kits are available for the basic motors, consisting of vanes,
For more information about our maintenance services,
please contact your local parker sales office.
O-rings and springs:
Lubrication and service life
Oil and oil mist are things which one tries to avoid to get the best possible
working environment. In addition, purchasing, installation and maintenance
of oil mist equipment costs money and, above all, time to achieve opti-
mum lubrication effect.
The P1V-A motor is equipped with vanes for intermittent
operation as standard for most common applications.
Service interval
The first service is due after approximately 500 hours of operation.
After the first service, the service interval is determined by the degree of
vane wear.
The following normal service intervals should be applied to in order to
guarantee problem-free operation in air motors working continuously at
load speeds.
Intermittent lubrication operation
Duty
cycle
70%
Max. duration of intermittent use
15 minutes
Oil volume
1 drop oil/Nm
3
Filtering 40 µm
app. 750 hours operation
Filtering 5 µm
app. 1,000 hours operation
Continuous lubrication operation
Oil volume
1 drop oil/Nm
3
Filtering 40 µm
app. 1,000 hours operation
Filtering 5 µm
app. 2,000 hours operation
Continuous lubrication operation
Oil
volume
Oil
free
Filtering 40 µm
app. 750 hours operation
Filtering 5 µm
app. 1,000 hours operation
Standard vanes (0, D):
For intermittent lubrication-free operation.
They can operate 70% of the time for up to 15 minutes without
lubrication.
With lubrication, these motors can operation 100% of the time.
"Black" vanes (C, E):
For continuous lubrication-free operation.
(To obtain the longest possible service life, we recommend no
oil in the air.)
Order code
Motor type
Motor
power
Watt
Vanes for
intermittent
lubrification
operation,
options "O & D"
Vanes for
continuous
lubrification
operation,
options "C & E"
P1V-A160A0900
1600
P1V-6/4450331B P1V-6/4450332B
P1V-A160D0300
1600
P1V-6/4450331D P1V-6/4450332D
P1V-A160B0140
1600
P1V-6/4450331E P1V-6/4450332E
P1V-A160B••••
1600
P1V-6/4450331B P1V-6/4450332B
P1V-A160H••••••
1600
P1V-6/4450331B P1V-6/4450332B
P1V-A160F••••••
1600
P1V-6/4450331B P1V-6/4450332B
P1V-A160G••••••
1600
P1V-6/4450331B P1V-6/4450332B
P1V-A160D••••••
1600
P1V-6/4450331B P1V-6/4450332B
P1V-A160E••••••
1600
P1V-6/4450331B P1V-6/4450332B
P1V-A320A0700
3200
P1V-6/4450341B P1V-6/4450342B
P1V-A320D0300
3200
P1V-6/4450341D P1V-6/4450342D
P1V-A320B0140
3200
P1V-6/4450341E P1V-6/4450342E
P1V-A320H••••••
3200
P1V-6/4450341B P1V-6/4450342B
P1V-A320F••••••
3200
P1V-6/4450341B P1V-6/4450342B
P1V-A320G••••••
3200
P1V-6/4450341B P1V-6/4450342B
P1V-A320D••••••
3200
P1V-6/4450341B P1V-6/4450342B
P1V-A320E••••••
3200
P1V-6/4450341B P1V-6/4450342B
P1V-A500A0600
5000
P1V-6/4450351B P1V-6/4450352B
P1V-A500D0300
5000
P1V-6/4450351D P1V-6/4450352D
P1V-A500B0145
5000
P1V-6/4450351E P1V-6/4450352B
P1V-A500H••••••
5000
P1V-6/4450351B P1V-6/4450352B
P1V-A500F••••••
5000
P1V-6/4450351B P1V-6/4450352B
P1V-A500G••••••
5000
P1V-6/4450351B P1V-6/4450352B
P1V-A500D••••••
5000
P1V-6/4450351B P1V-6/4450352B
P1V-A500E••••••
5000
P1V-6/4450351B P1V-6/4450352B
P1V-A600A0700
6000
P1V-6/4450351B P1V-6/4450352B
P1V-A600D0350
6000
P1V-6/4450351D P1V-6/4450352D
P1V-A600B0160
6000
P1V-6/4450351E P1V-6/4450352E
P1V-A900A0600
9000
P1V-6/440246C
-
P1V-AJ00A0600
18000
P1V-6/440246B
-
•••••• Rest of the air motor order code
Содержание P1V-A160B Series
Страница 11: ...11 www parker com euro_pneumatic...