Parker Hannifin Manufacturing Srl
user’s manual MDC
32
5.1.1
112B
Value capture
At every positive, or negative (b39.4=1), front of digital input 1, the value of Pr63:62 is
captured and stored in Pr68:69 and b70.15 is set to 1 to signal the event. b70.15 is not reset
automatically.
Analogous situation, at every positive, or negative (b39.3=1), front of digital input 0, the
value of Pr63:62 is captured and stored in Pr58:59 and b70.14 is set to 1 to signal the event.
b70.14 is not reset automatically.
The function is always enabled if the bit b39.6 is equal to 1. Otherwise when the bit b39.6 is
set to 0, the value capture function needs the reset of the signal event bit: b70.14 and b70.15.
N.B. this function requires b42.15=1.
Содержание MDC Series
Страница 1: ...User s manual Rev 0 1 August 2012 MDC MotorNet DC www runcheng net www runcheng net...
Страница 13: ...Parker Hannifin Manufacturing Srl user s manual MDC 13 3 3 Motor data...
Страница 16: ...Parker Hannifin Manufacturing Srl user s manual MDC 16...
Страница 17: ...Parker Hannifin Manufacturing Srl user s manual MDC 17...
Страница 18: ...Parker Hannifin Manufacturing Srl user s manual MDC 18...
Страница 22: ...Parker Hannifin Manufacturing Srl user s manual MDC 22 4 5 Hybrid cable Connection PSI MDC...
Страница 57: ...www runcheng net www runcheng net...