Anti-cavitation check valve :
This valve is included in the
uni-rotational motor only.
The check valve assembly
is not a serviceable part and
must be replaced in case of
failure.
3 . 4 . VAlVeS :
end cap with opposite ports
end cap with side ports
Check valve assembly = S24 - 94046 - 0
(includes the O ring)
conversions
Check valve assembly = S24 - 94046 - 0
(includes the O ring)
TigHTening Torque :
50 Nm
36.8 Ft.lbs
LUBRICATE
WITH
C
LE
AN
HY
DRAULIC FLU
ID
SU
ITA
B
LE