4.    Switching functions

Hysteresis function: 

If the level fl uctuates around 
the nominal value, the hysteresis 
keeps the switch status of the 
outputs stable. 
When the level is rising, 
the output switches when it reaches 
the respective switching point (SP); 
if the level falls again, 
the output switches back only 
if the reverse switching point (rSP) 
is reached. 
(see menu point 

FunC, SP, rSP

)

 

Window function

The window function allows the 
monitoring of a defi ned range. 

If the level is between 
the switching point (SP) and 
the reverse switching point (rSP), 
the output is activated.
(see menu point 

FunC

,

 SP

,

 rSP

)

Error function

Switch output  2 can be used optionally as an error output 
to display level switch function errors. As an error output it is 
normally closed, and in case of errors ( 

Er1

Er3

 ) it is open. 

At the same time LED II lights up. 
The display and the error output remain active until the error 
is cleared. (See menu point 

Err

 

It conforms to DESINA when used with 
a 4-pole M12x1 connecting plug

5.    Analogue output

The level switch has two standardised output signals 
from 0-20mA or 4-20mA.
 
This is a prerequisite for

 

compatibility with existing systems 

Example for display in %: 

Example for display in mm:

L1 = length of the sensor

L2 = activ range

SensoControl

UNIT

UNIT

=

=

II

I

40

L2

L1

40

Of

fset

SCLSD-250

SCLSD-370

SCLSD-520

mm/inch

%

SensoControl

UNIT

UNIT

=

=

=

II

I

SET1

SCLSD-XXX

mm/inch

%

SET0