FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR
SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL
INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide
product and/or system options for further investigation by users having technical expertise. It is important that you analyze
all aspects of your application, including consequences of any failure, and review the information concerning the product or
system in the current product catalogue. Due to the variety of operating conditions and applications for these products or
systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products
and systems and assuring that all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing,
are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
Installation IQAN-LST
Wiring diagram
task oriented control
or expansion module
IQAN-LST
Publ.no: HY17-8301-IS/UK
Ed. 04/2009
For further information see:
HY17-8364/UK Instructions IQAN-LST
start
start
stop
stop
max
max
min
min
A
A
B
B
Enter
Enter
Adjust
Adjust
SETUP - push
1 sec.
®
TOC2
Slope
Slope
Curren
t
Curren
t
Dual sensor output
(89/336/EEC)
0
20
40
60
80
-20
-40
-60
-80
o
-40 - +70 C
90% Vs
50% Vs
10% Vs
VDC out
-100%
100%
Neutral
position
Output
B
Output
A
Deflection
WARNING
Mating connector kit: 5031097
Pin #
Signal/Function
C1
1
GND
2
POWER (+5Vdc)
3
OUT-A (primary)
4
OUT-B (secondary)
Pin #
Signal/Function
C1
Pin #
Signal/Function
4
OUT-B (secondary)
1
GND
3
OUT-A (primary)
2
POWER (+5Vdc)
Mating connector kit: 5031113
-S (Saab AMP/Tyco)
-D (Deutsch)
Eng no: M5010026A